Source page 530 · section 546/1965 · approximately 4 minutes
10 - 130
10 - 130
keep the rows of plates apart, the electrolyte, and an adjustable-frequency modified pseudo-sinewave inverter for
the drive electronics. A total of 101 plates 6 inches square are used to give a large surface area. These have
their surfaces scoured with coarse sandpaper in an "X" pattern to give a fine crosshatch grain which added fine
sharp points to the surfaces.
This is found to improve the efficiency of the electrolysis. The box has two threaded ports, a small one for
injecting replacement distilled water, and a larger one for extracting the hydroxy gas. Under the top cover is a
piece of plastic matting to prevent sloshing. It is very important to keep the electrolyte level below the tops of the
plates to prevent current bypassing any cells and creating excessive water vapour.
Bob places a 5 Pounds per Square Inch cut-off switch in a tee on the water injection port that shut the drive
electronics down when the pressure in the unit hit 5 PSI. This allows the unit to be able to supply on demand
without building up too much pressure in low-demand situations. He builds a bubbler from a large home cartridge
type water-filter housing to prevent any backfire from travelling back up the gas feed pipe to the electrolyser.
Without some sort of bubbler there is the risk of the electrolyser exploding if a flame front from the engine flows
back to it and the bubbler washes out any traces of electrolyte vapour from the hydroxy gas.
The copper mesh screens designed for welding gasses will not work as hydrogen has a much higher flame
propagation speed which passes straight through the copper mesh. The bubbler should be placed close to the
engine so as to limit the amount of recombination of the gasses from monatomic to diatomic varieties. The
hydroxy gas should be fed to the vapour portion of a Liquid Petroleum Gas carburettor system. The carburettor
will have to be modified for hydrogen use (different mixture rate than propane) and adjusted for best performance
with the system running.
Bob found that the best electrolytes to use were Sodium Hydroxide (NaOH) and Potassium Hydroxide (KOH).
While Sodium Hydroxide works well and is much easier to get (‘Red Devil’ lye found in most department stores)
than the slightly more efficient Potassium Hydroxide. Whatever is used, be very careful what construction
materials are used. Make absolutely sure that they are compatible with the chosen electrolyte (Plexiglas acrylic
sheet was what Bob used). Never use glass containers for mixing or storing Potassium Hydroxide as most of
these containers do not have glass of high enough quality to withstand a caustic solution.
Bob never had the chance to drive the test Chrysler on the road with this system. Instead, he placed the rear end
up on jack-stands and ran the engine under no-load conditions in drive just to test and tune the system and get an
idea of how well the engine held up on the hydrogen fuel. The vehicle was run for a mileometer recorded
distance of one thousand miles in this set-up with the hydrolysis being fully powered by the alternator of the
vehicle. With the vehicle running at idle, the drive electronics consumed approximately 4 to 4.3 Amps @ 13.8 V
DC. With the rear wheels off of the ground, and the engine running with the vehicle speedometer registering 60
mph, the drive electronics drew approximately 10.9 to 11.6 Amps @ 13.8 V DC.
The unit does not use "normal brute force" electrolysis when operating in high efficiency mode. It relies mainly on
a chemical reaction that takes place between the electrolyte used and the metal plates, which is maintained by
electrical energy applied and stimulated into higher efficiency by the application of multiple harmonic resonances
which help to "tickle" the molecules apart. Multiple cells in series are used to lower the voltage per cell and limit
the current flow in order to reduce the production of water vapour. It relies on the large surface area of the total
number of cells to get the required volume of fuel vapour output.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.