Source page 543 · section 560/1965 · approximately 2 minutes
10 - 143
10 - 143
The 100 ohm resistor and the 100 microfarad capacitor are there to iron out any ripples in the voltage supply to
the circuit, caused by fierce pulses in the power drive to the electrolysis cell. The capacitor acts as a reservoir of
electricity and the resistor prevents that reservoir being suddenly drained if the power supply line is suddenly, and
very briefly, pulled down to a low voltage. Between them, they keep the voltage at point “A” at a steady level,
allowing the 555 chip to operate smoothly.
The very small capacitor “B” is wired up physically very close to the chip. It is there to short-circuit any stray, very
short, very sharp voltage pulses picked up by the wiring to the chip. It is there to help the chip to operate exactly
as it is designed to do, and is not really a functional part of the circuit. So, for understanding how the circuit
works, we can ignore them and see the circuit like this:
This circuit generates output pulses of the type shown in green with the voltage going high, (the “Mark”) and low
(the “Space”). The 47K variable resistor (which some people insist on calling a “pot”) allows the length of the
Mark and the Space to be adjusted from the 50 - 50 shown, to say, 90 - 10 or any ratio through to 10 - 90. It
should be mentioned that the “47K” is not at all critical and these are quite likely to be sold as “50K” devices.
Most low cost components have a plus or minus 10% rating which means that a 50K resistor will be anything from
45K to 55K in actual value.
The two “1N4148” diodes are there to make sure that when the Mark/Space 47K variable resistor is adjusted, that
it does not alter the frequency of the output waveform in any way. The remaining two components: the 10K
variable resistor and the 47 microfarad capacitor, both marked in blue, control the number of pulses produced per
second. The larger the capacitor, the fewer the pulses per second. The lower the value of the variable resistor,
the larger the number of pulses per second.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.