REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 551 · section 568/1965 · approximately 3 minutes

10 - 151

10 - 151

Dave, who built this replication, suggests various improvements. Firstly, Stan Meyer used a larger number of
tubes of greater length. Both of those two factors should increase the gas production considerably. Secondly,
careful examination of video of Stan’s demonstrations shows that the outer tubes which he used had a
rectangular slot cut in the top of each tube:

Some organ pipes are fine-tuned by cutting slots like this in the top of the pipe, to raise it’s pitch, which is it’s
frequency of vibration. As they have a smaller diameter, the inner pipes in the Meyer cell will resonate at a higher
frequency than the outer pipes. It therefore seems probable that the slots cut by Stan are to raise the resonant
frequency of the larger pipes, to match the resonant frequency of the inner pipes. If you want to do that, hanging
the inner tube up on a piece of thread and tapping it, will produce a sound at the resonant pitch of the pipe.
Cutting a slot in one outer pipe, suspending it on a piece of thread and tapping it, will allow the pitch of the two
pipes to be compared. When one outer pipe has been matched to your satisfaction, then a slot of exactly the
same dimensions will bring the other outer pipes to the same resonant pitch. It has not been proved, but it has
been suggested that only the part of the outer pipe which is below the slot, actually contributes to the resonant
frequency of the pipe. That is the part marked as “H” in the diagram above. It is also suggested that the pipes will
resonate at the same frequency if the area of the inside face of the outer pipe (“H” x the inner circumference)
exactly matches the area of the outer surface of the inner pipe. It should be remembered that as all of the pipe
pairs will be resonated with a single signal, that each pipe pair needs to resonate at the same frequency as all the
other pipe pairs.

It is said that Stan ran his VolksWagen car for four years, using just the gas from four of these units which had
pipe pairs 16-inchs long. A very important part of the cell build is the conditioning of the electrode tubes, using
tap water. Ravi in India suggests that this is done as follows:

1. Do not use any resistance on the negative side of the power supply when conditioning the pipes.
2. Start at 0.5 Amps on the signal generator and after 25 minutes, switch off for 30 minutes
3. Then apply 1.0 Amps for 20 minutes and then stop for 30 minutes.
4. Then apply 1.5 Amps for 15 minutes and then stop for 20 minutes.
5. Then apply 2.0 Amps for 10 minutes and afterwards stop for 20 minutes.
6. Go to 2.5 Amps for 5 minutes and stop for 15 minutes.
7. Go to 3.0 Amps for 120 to 150 seconds. You need to check if the cell is getting hot...if it is you need to reduce
the time.

After the seven steps above, let the cell stand for at least an hour before you start all over again.

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.