---
canonical: "https://yogababe.online/reading/BATCH2-006/57"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 57 · 2 - 5 | Rejuvenati"
content_sha256: "92db1a631734912566bab343d244676325e97ba8aec76457c5320da6e9a70d64"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 55 · section 57/1965 · approximately 4 minutes

## 2 - 5

2 - 5  
The iron core loses power when pulsed, due to eddy currents flowing around inside the iron. The same  
effect applies to transformer frames, so they are constructed of thin sheets of metal, each insulated from its  
neighbours. It is suggested therefore, that the core of an electromagnet would be more efficient if it were not  
a solid piece of metal. It can be constructed from ‘soft’ iron wires cut to the appropriate length and insulated  
with lacquer which can withstand high voltages or failing that, enamel paint or nail varnish.

The number of electromagnets is a matter of personal choice. The sketch above shows eight  
electromagnets per stator, which gives the motor eight drive pulses per rotation. The motor works well with  
as few as two electromagnets. As shown, there can be as many rotors and stators in the motor as you  
choose. The gap between the electromagnet and the rotor magnets is of major importance and needs to be  
as small as it is practical to make it as magnetic force drops off very rapidly with distance from the magnet.  
The spacing of the rotor magnets needs to match exactly, the spacing of the electromagnets so that when an  
electrical pulse is applied, there is a rotor magnet opposite each electromagnet. There could be twice as  
many permanent magnets as electromagnets, or three times as many if you prefer.

The timing of the electrical pulses can be taken directly from the pick-up coil bank as its voltage rises as the  
magnets pass by. This varying voltage waveform can be sharpened up by using a Schmitt trigger circuit.  
The exact synchronisation can be governed by two monostables, one to set the delay before the pulse starts  
and one to control the exact length of the pulse.

Alternatively, a separate movable pick-up coil or Hall-effect sensor can be used and its position adjusted to  
give optimum operation. Another variation is to use a hole through one rotor beside each magnet and  
positioning an LED to shine through the holes, on to an opto device, to mark the rotation position.

There is a large amount of practical information on the construction of this type of motor at the web site  
[http://members.fortunecity.com/freeenergy2000/adamsmotor.htm.](http://members.fortunecity.com/freeenergy2000/adamsmotor.htm.) For instance, Tim Harwood shares his  
experience having constructed many such motors and run many tests. A few of his observations are:

1\. Ohm’s Law does not apply to a correctly tuned Adams motor as the current flow is ‘cold energy’ rather  
than conventional energy being used. The greater the load on a properly set-up and tuned motor, the colder  
the stator coils and driving transistors become - the reverse of the situation for conventional energy where  
increased load requires increased current which produces increased heat. Small diameter wire can  
therefore be used for the electromagnet windings.

2\. The cross-sectional area of each electromagnet core should be one quarter of the area of each rotor  
magnet.

3\. The depth of the electromagnet winding should be the same as the maximum distance one rotor magnet  
can pull a paper-clip to itself.

4\. Electromagnet wire of 24 AWG (0.511 mm dia, about 25 SWG) is a suitable size for windings.

5\. The stator windings in series should have a (presumably DC) resistance of about ten ohms.

6\. He uses steel nails with a 3/8” head, 100 mm shaft for the electromagnet cores. He selects these  
carefully from a large supply, to pick those with the best magnetic characteristics and which have a head  
slightly angled away from the official ninety degrees of a correctly manufactured head.

7\. He finds that a electrical tape cover to both the electromagnet core before winding and outside the  
winding on completion, help the characteristics of the electromagnets.

8\. He uses outward facing rotor magnets only and finds that having the South pole facing the electromagnets  
gives a slightly better result.

9\. He tunes his motors using 12 Volts and then increases the voltage to 240 Volts.

10\. If you use a Hall-effect semiconductor to trigger the timed pulses, he suggests buying several as they are  
very easy to damage.

11\. The construction of the motor frame, supports, enclosure, etc. should avoid all magnetic materials as  
these can make the tuning difficult and they may block the tapping of ‘cold’ electricity.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00057)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/57) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
