Source page 645 · section 665/1965 · approximately 4 minutes
12 - 10
12 - 10
They used a sensitive meter to measure the current. This meter is built so that the needle is in a central
position if no current is flowing. With a positive current flowing, the needle deflects to the right. With a
negative current flowing, the needle moves to the left. They then connected a variable resistor ‘VR1’ across
the same battery which was powering the circuit. The top end of VR1 is at +12 Volts (they called that ‘a
potential of +12 Volts’) and the bottom end of VR1 is at zero volts or ‘a potential of zero volts’.
By moving the slider of VR1, any voltage or ‘potential’ from zero volts to +12 Volts could be selected. To
measure the voltage at point ‘A’ without drawing any current from the circuit, they would connect the meter
as shown and adjust the variable resistor until the meter reading was exactly zero.
Since the meter reading is zero, the current flowing through it is also zero and the current taken from the
circuit is zero. As no current is being taken from the circuit, the measurement is not affecting the circuit in
any way - very clever. The voltage on the slider of VR1 exactly matches the voltage at point ‘A’, so with a
calibrated scale on the variable resistor, the voltage can be read off.
The slick piece of equipment made up from the battery, the variable resistor and the meter was used to
measure the ‘potential’ (voltage) at any point and so was called a ‘potentiometer’. So, please humour me by
calling a variable resistor a ‘variable resistor’ and not a ‘potentiometer’. As I said before, this is not at all
important, and if you want to, you can call a variable resistor a ‘heffalump’ so long as you know how it works.
Semiconductors. This section deals with discrete semiconductors. A later section deals with ‘Integrated
Circuits’ which are large-scale semiconductor devices.
ORP12 Light-dependent resistor. This device has a high resistance in the dark and a low resistance in
bright light. It can be placed in a circuit to create a switch which operates with an increase in light level or a
decrease in light level:
In this version, the voltage at point ‘A’ controls the circuit. In darkness, the ORP12 has a resistance ten
times greater than that of R1 which is 12,000 ohms. Consequently, the voltage at point ‘A’ will be high. As
the light level increases, the resistance of the ORP12 falls, dragging the voltage at point ‘A’ downwards. As
the variable resistor ‘VR1’ is connected from point ‘A’ to the ground rail (the -ve of the battery), its slider can
be moved to select any voltage between 0 Volts and the voltage of ‘A’. A slider point can be chosen to make
the transistor switch off in daylight and on at night. To make the circuit trigger when the light level increases,
just swap the positions of R1 and the ORP12.
The transistor shown is a BC109 although most transistors will work in this circuit. The BC109 is a cheap,
silicon, NPN transistor. It can handle 100mA and 30V and can switch on and off more than a million times
per second. It has three connections: the Collector, marked ‘c’ in the diagram, the Base, marked ‘b’ in the
diagram and the Emitter, marked ‘e’ in the diagram.
As mentioned before, it has a very high resistance between the collector and the emitter when no current
flows into the base. If a small current is fed into the base, the collector/emitter resistance drops to a very low
value. The collector current divided by the base current is called the ‘gain’ of the transistor and is often
called ‘hfe’. A transistor such as a BC109 or a BC108 has a gain of about 200, though this varies from
actual transistor to actual transistor. A gain of 200 means that a current of 200mA passing through the
collector requires a current of 1mA through the base to sustain it. Specific information on the characteristics
and connections of semiconductors of all kinds can be obtained free from the excellent website
www.alldatasheet.co.kr which provides .pdf information files.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.