canonical: "https://yogababe.online/reading/BATCH2-006/667"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 667 · 12 - 12 | Rejuvenati"
content_sha256: "63f13b8e4a1f17093c8f5dc5ac822d124f81a471b370c5b3bad4266450034ea7"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 647 · section 667/1965 · approximately 2 minutes

## 12 - 12

12 - 12  
how the circuit works. Either of the two previous circuits can operate as a rain detector. A suitable sensor  
can easily be made from a piece of strip board with alternate strips connected together to form an interlacing  
grid:

Here, if a raindrop bridges between any two adjacent strips, the circuit will trigger and sound a warning.

The transistors in the circuit above are connected with their emitter(s) connected to the ground rail (the lower  
battery line shown in any circuit is considered to be “ground” unless it is specifically shown elsewhere). This  
connection method is called ‘common emitter’. The following circuit uses the transistor connected in ‘emitter  
follower’ mode. This is where the emitter is left to follow the base voltage - it is always 0.7V below it unless  
the base itself is driven below 0.7V:

This is almost the same as the light-operated circuit shown earlier. In this variation, the transistors are wired  
so that they work as an ‘emitter-follower’ which follows the voltage at point ‘A’ which rises as the light level  
drops and the resistance of the ORP12 increases. This causes the voltage across the relay to increase until  
the relay operates and closes its contacts. A relay is a voltage-operated mechanical switch which will be  
described in more detail later on.

The disadvantage of the above circuit is that as the light level decreases, the current through the relay  
increases and it may be a significant amount of current for some considerable time. If it was intended to  
power the unit with a battery then the battery life would be far shorter than it need be. What we would like, is  
a circuit which switched rapidly from the Off state to the On state even though the triggering input varied only  
slowly. There are several ways to achieve this, one of them being to modify the circuit to become a ‘Schmitt  
Trigger’: