Source page 656 · section 676/1965 · approximately 4 minutes
12 - 21
12 - 21
An interesting point is that as a solenoid pulse is terminated, its pull is briefly changed to a push due to the
weird nature of coils. If the timing of the pulses is just right on this motor, that brief push can be used to
increase the power of the motor instead of opposing the motor rotation. This feature is also used in the
Adams motor described in the ‘Free-Energy’ section of this document.
The strength of the magnetic field produced by the solenoid is affected by the number of turns in the coil, the
current flowing through the coil and the nature of what is inside the coil ‘former’ (the tube on which the coil is
wound). In passing, there are several fancy ways of winding coils which can also have an effect, but here
we will only talk about coils where the turns are wound side by side at right angles to the former.
1. Every turn wound on the coil, increases the magnetic field. The thicker the wire used, the greater the
current which will flow in the coil for any voltage placed across the coil. Unfortunately, the thicker the wire,
the more space each turn takes up, so the choice of wire is somewhat of a compromise.
2. The power supplied to the coil depends on the voltage placed across it. Watts = Volts x Amps so the
greater the Volts, the greater the power supplied. But we also know from Ohm’s Law that Ohms = Volts /
Amps which can also be written as Ohms x Amps = Volts. The Ohms in this instance is fixed by the wire
chosen and the number of turns, so if we double the Voltage then we double the current.
For example: Suppose the coil resistance is 1 ohm, the Voltage 1 Volt and the Current 1 Amp. Then the
power in Watts is Volts x Amps or 1 x 1 which is 1 Watt.
Now, double the voltage to 2 Volts. The coil resistance is still 1 ohm so the Current is now 2 Amps. The
power in Watts is Volts x Amps or 2 x 2 which is 4 Watts. Doubling the voltage has quadrupled the power.
If the voltage is increased to 3 Volts. The coil resistance is still 1 ohm so the Current is now 3 Amps. The
power in Watts is Volts x Amps or 3 x 3 which is 9 Watts. The power is Ohms x Amps squared, or Watts =
Ohms x Amps x Amps. From this we see that the voltage applied to any coil or solenoid is critical to the
power developed by the coil.
3. What the coil is wound on is also of considerable importance. If the coil is wound on a rod of soft iron
covered with a layer of paper, then the magnetic effect is increased dramatically. If the rod ends are tapered
like a flat screwdriver or filed down to a sharp point, then the magnetic lines of force cluster together when
they leave the iron and the magnetic effect is increased further.
If the soft iron core is solid, some energy is lost by currents flowing round in the iron. These currents can be
minimised by using thin slivers of metal (called ‘laminations’) which are insulated from each other. You see
this most often in the construction of transformers, where you have two coils wound on a single core. As it is
convenient for mass production, transformers are usually wound as two separate coils which are then placed
on a figure-of-eight laminated core.
Transformers are used to alter the voltage of any alternating current power source. If the alteration
increases the output voltage, then the transformer is called a ‘step-up’ transformer. If the output voltage is
lower than the input voltage then it is called a ‘step-down’ transformer. If the voltages are the same, it is
called an ‘isolation’ transformer. A common construction looks like this:
The Coil bobbin sits on the section of the laminations marked ‘A’ above. The coil is wound on its bobbin
former, first one winding and then the second winding. The bobbin is then placed on the central part of the
‘E’ shaped laminations and then completely surrounded by the laminations when the crossbar is placed on
the top. The mounting strap is used to hold the two sets of laminations together and provide mounting lugs
for attaching the transformer to a chassis. There are typically, twenty laminations in each set and every
lamination is insulated from the adjoining laminations.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.