Source page 674 · section 694/1965 · approximately 2 minutes
12 - 39
12 - 39
Astable Frequencies
100
470
1K
4.7K
10K
47K
100K
470K
1M
0.1 mF
72,000
Hz
15,319
Hz
7,200
Hz
1,532
Hz
720
Hz
153
Hz
72
Hz
15
Hz
7.2
Hz
0.47 mF
15,319
Hz
3,259
Hz
1,532
Hz
326
Hz
153
Hz
33
Hz
15
Hz
3.3
Hz
1.5
Hz
1.0 mF
7,200
Hz
1,532
Hz
720
Hz
153
Hz
72
Hz
15
Hz
7.2
Hz
1.5
Hz
1.4
secs
2.2 mF
3,272
Hz
696
Hz
327
Hz
70
Hz
33
Hz
7
Hz
3.3
Hz
1.4
secs
3
secs
4.7 mF
1,532
Hz
326
Hz
153
Hz
33
Hz
15
Hz
3.3
Hz
1.5
Hz
3
secs
6.7
secs
10 mF
720
Hz
153
Hz
72
Hz
15
Hz
7.2
Hz
1.5
Hz
1.4
secs
6.7
secs
14
secs
22 mF
327
Hz
70
Hz
33
Hz
7
Hz
3.3
Hz
1.4
secs
3
secs
14
secs
30
secs
47 mF
153
Hz
33
Hz
15
Hz
3.3
Hz
1.5
Hz
3
secs
6.7
secs
30
secs
65
secs
100 mF
72
Hz
15
Hz
7.2
Hz
1.5
Hz
1.4
secs
6.7
secs
14
secs
65
secs
139
secs
220 mF
33
Hz
7
Hz
3.3
Hz
1.4
secs
3
secs
14
secs
30
secs
139
secs
307
secs
470 mF
15
Hz
3.3
Hz
1.5
Hz
3
secs
6.7
secs
30
secs
65
secs
307
secs
614
secs
1,000 mF
7.2
Hz
1.5
Hz
1.4
secs
6.7
secs
14
secs
65
secs
139
secs
614
secs
2,200 mF
3.3
Hz
1.4
secs
3
secs
14
secs
30
secs
139
secs
307
secs
4,700 mF
1.5
Hz
3.3
secs
6.7
secs
30
secs
65
secs
307
secs
614
secs
10,000 mF
1.4
secs
6.7
secs
14
secs
65
secs
139
secs
614
secs
Note: The high leakage of large value electrolytic capacitors prevents them being used with high value
resistors in timing circuits. Instead, use a smaller capacitor and follow the timing circuit with a “divide-by-N”
chip to give accurately timed long periods. Not all 555 chips have a manufacturing quality sufficient for them
to operate reliably above 20,000 Hz, so for the higher frequencies the chip needs to be selected after testing
its actual performance.
We can also wire the 555 to give a variable mark/space ratio while holding the frequency of the oscillation
fixed:
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.