Source page 679 · section 699/1965 · approximately 3 minutes
12 - 44
12 - 44
This circuit is set up as evening falls. We want the relay to have minimum voltage across it in daylight, so
the voltage at point ‘A’ needs to be higher than the voltage at point ‘B’. As the 1K variable resistor is across
the supply voltage, its slider can be set to any voltage between 0 Volts and +12 Volts. To make this easy to
do, we choose a ‘linear’ variable resistor as the logarithmic variety would be hard to adjust in this application.
With the ‘linear’ version, each 1 degree of rotation of the resistor shaft causes the same change in
resistance, anywhere along the range. This is not the case for the logarithmic variety.
Anyhow, we adjust the variable resistor downwards until the relay voltage drops to a minimum. When the
light level has fallen to the level at which we wish the circuit to trigger, we adjust the variable resistor to make
the relay click on. The 741 chip has a very rapid output voltage swing when the input voltages swap over, so
the relay switching will be decisive. The switching can be made even more positive by adding a resistor
between the output and point ‘B’. This acts like a Schmitt trigger when switching occurs by providing some
additional positive feedback, lifting the voltage at point ‘B’.
If you wish the circuit to trigger on a rising light level, just swap the positions of the 10K resistor and the
ORP12 light-dependent resistor. The same circuit will operate as a temperature sensing circuit by
substituting a ‘thermistor’ (which is a temperature-dependent resistor) for the ORP12.
If we would like the circuit to act as a burglar alarm, we could use the same circuit like this:
The circuit is still controlled by the voltage at point ‘A’. Under normal circumstances, this voltage will be near
+6 Volts (produced by the two 10K resistors and the 100K resistor). The upper switch marked ‘NC’ for
‘Normally Closed’, represents a chain of, say, magnetic switches attached to doors and windows. If any of
these are opened, then the voltage at point ‘A’ will be dictated by the lower 10K resistor in series with the
100K resistor. This will cause the voltage at ‘A’ to fall instantly to a low value, triggering the circuit.
The ‘NO’ switch (‘Normally Open’) represents one or more pressure-operated switches under carpets or
rugs and/or switches which get brushed when doors are swung open, etc. These switches are wired in
parallel across each other and if any of them is closed for even a millionth of a second, the voltage at point
’A’ will be pulled down by the 1K resistor and the circuit will be triggered.
The circuit can be latched on in any one of a variety of ways. One relay contact can be used to hold the
relay on or hold the voltage at ‘A’ low. A transistor can be wired across the relay to hold the circuit on, etc.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.