canonical: "https://yogababe.online/reading/BATCH2-006/700"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 700 · 12 - 45 | Rejuvenati"
content_sha256: "ddf4f98315cb0c9d9722079e2c1ca4984196eba2985db3620127c0abb83bf645"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 680 · section 700/1965 · approximately 3 minutes

## 12 - 45

12 - 45  
etc. If this is done, the circuit will remain in its triggered state until the supply voltage is interrupted. You  
might prefer to use a 555 chip to limit the length of time the alarm sounds to three minutes or so.

An alternative to using a relay or semiconductor latch is to use a Silicon Controlled Rectifier usually referred  
to as an ‘SCR’ or ‘Thyristor’. This device is normally “off” with a very high resistance to current flow. If it is  
switched on by applying a voltage to its Gate connection, it stays continuously on until some external device  
stops current flowing through it. The following circuit shows how it operates:

When the voltage is first applied to the circuit by closing switch S2, the SCR is in its OFF state so no current  
is supplied to the load. If the press-button switch S1 is pressed, a current is fed into the Gate of the SCR,  
turning it ON. When switch S1 is allowed to open, the SCR remains in its ON state and it will stay that way  
until the current through it is cut off. Opening switch S2 cuts off the current to the load and the SCR returns  
to its OFF state. A very valid question would be: “Why have an SCR at all and just turn the load on and off  
with switch S2?”. The answer is that switch S1 might be the under-carpet pressure pad of a burglar-alarm  
and it might be operated some hours after switch S2 was closed to activate the alarm system. Stepping off  
the pressure pad does not stop the alarm sounding.

While this sort of DC latching action is useful, it is more common for an SCR to be used in an AC circuit. For  
example, take the circuit shown here:

The 120 volt AC supply coming in from the right hand side, is converted to positive-going sine-wave pulses  
by the diode bridge. This pulsing voltage is applied to the Load/SCR path. If the voltage at pin 3 of the 555  
chip is low, then the SCR will remain OFF and no current will be fed to the load device. If the voltage on pin  
3 goes high and the voltage applied to the Load/SCR chain is high, then the SCR will be switched ON,  
powering the load until the pulsing voltage drops to its zero level again some 1/120 of a second later.

The 555 chip is connected to form a monostable multivibrator and the timing components (the 120K resistor  
and the 10nF capacitor) cause it to output a 1 millisecond pulse which is long enough to trigger the SCR into  
its ON state, but short enough to have finished before the mains pulse reaches its zero-voltage level again.  
The 555 chip is triggered by the rising mains voltage being passed to its pin 2 through the voltage-divider  
100K and 120K pair of resistors, and that synchronises it with the AC waveform. Pin 4 of the 555 chip can  
be used to switch the load power on and off.