Phil Wood, has many years of experience working with all varieties of electric motor, has come up with a
very clever circuit variation for the RotoVerter system. His design has a 240 volt Prime Mover motor driven
with 240 volt AC. The revised circuit now has automated start-up and it provides an extra DC output which
can be used to power additional equipment. His circuit is shown here:
Phil specifies the diode bridges as 20 amp 400 volt and the output capacitor as 4000 to 8000 microfarads
370 volt working. The ON/OFF switch on the DC output should be 10 amp 250 volt AC working. The circuit
operates as follows:
The charge capacitor “C” needs to be fully discharged before the motor is started, so the press-button switch
is pressed to connect the 1K resistor across the capacitor to discharge it fully. If you prefer, the press-button
switch and resistor can be omitted and the switch to the DC load closed before the AC input is applied. The
switch must then be opened and the AC connected. The starting capacitor “S” and capacitor “R” both
operate at full potential until capacitor “C” begins to charge. As capacitor “C” goes through its charging
phase, the resistance to capacitors “R” and “S” increases and their potential capacitance becomes less,
automatically following the capacitance curve required for proper AC motor operation at start-up.
After a few seconds of run time, the output switch is operated, connecting the DC load. By varying the
resistance of the DC load, the correct tuning point can be found. At that point, the DC load resistance keeps
both of the capacitors “R” and “S” operating at a potentially low capacitance value.
The operation of this circuit is unique, with all of the energy which is normally wasted when the AC motor is
starting, being collected in the output capacitor “C”. The other bonus is where a DC load is powered for free
while it keeps capacitors “R” and “S” in their optimum operating state. The DC load resistance needs to be
adjusted to find the value which allows automatic operation of the circuit. When that value has been found
and made a permanent part of the installation, then the switch can be left on when the motor is started
(which means that it can be omitted). If the switch is left on through the starting phase, capacitor “C” can be
a lower value if the DC load resistance is high enough to allow the capacitor to go through its phase shift.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.