We separated this somewhat magnetic sand into a pile, sifted it through a window screen, and sorted that
with the magnet one more time. The remaining black sand sticking to the magnet was nearly pure magnetite.
A quick test of any local dirt pile with a neodymium magnet should reveal whether your sand contains
magnetite. If not, try dragging the magnet along the sandy bottom of a local river. Any deposits of black sand
on the river bottom are most likely nearly pure magnetite.
The clearance between the stator coils and the armature surface is very important. It must be extremely
close (within
1/16 inch; 1.5 mm) without allowing the magnets in the armature to touch the stator. Our model is
actually a bit sloppy—the clearances are more like an
1/8 inch (3 mm). Tighter tolerances would produce
more power.
Wiring Configuration
The completed stator consists of two identical sets of four coils. For our wind generator, we connected the
stator halves in parallel for more current (amperage). Connecting them in series would double the voltage
produced, but halve the amperage. For low wind speeds, a series connection would be the best—the
alternator would reach charging voltage at slower speeds. At higher speeds, a parallel connection is optimum
for producing the most amperage.
An ideal system would contain a regulator that switched the stator connections from series to parallel when
the unit began to spin fast enough. As is the case with many home-brew and commercial wind turbines, we
eliminated this entirely, sacrificing a small amount of efficiency for much greater simplicity and reliability.
Many people have experimented with such regulators, both solid state and mechanical.
Alternator Performance
We were really surprised by this alternator’s performance. We could easily spin it with our fingers and get 12
volts or higher. A cordless drill attached to the shaft would light up a 25 watt, 12 V DU light bulb easily. This
might not seem breath-taking, but considering the simplicity of the project and one-day construction time, we
were quite impressed.
Our 100 watt rating for the Wood 103 is probably right on, considering the performance we got during testing,
and the way commercial wind generator manufacturers rate their products. Our data acquisition system was
pretty simple - multimeters and people with pencils and paper to watch them and record measurements.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.