canonical: "https://yogababe.online/reading/BATCH2-006/798"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 798 · 14 - 38 | Rejuvenati"
content_sha256: "355fedee3699d6869f8009eab799ca88e932dffae0cb6e268dcca17445ffdb82"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 778 · section 798/1965 · approximately 4 minutes

## 14 - 38

14 - 38

The cooking container primarily tested is a glass canning jar that has been painted flat black. The black  
paint allows the jar to absorb the sun’s rays. The canning jar works well due to the added pressure-cooker  
effect caused by the rubber ring on the inside of the lid. A black-enamel pot and a black-painted stainless  
steel canister were also used. We found immediately that raising the vessel off the bottom of the cooker  
using a rabbit-wire stand provided more rapid and even heating than the wooden block used previously.  
Placing the jar or pot on a wire stand allows as much reflected light onto the cooking vessel as possible.  
This allows even the bottom of the cooking container to absorb thermal energy that is reflected off the lower  
portion of the funnel.

Two methods of closing the cookers off from convection currents were used. It is important to keep the air  
that surrounds the container from circulating, thus keeping the cooking container from being cooled by  
convection currents or breezes. This first method used was to enclose the cooking vessel and wire stand in  
a clear plastic bag, such as a heat resistant Reynolds Oven Bag. It is important to make sure that the bag is  
not touching the cooking vessel, so once the vessel is placed into the clear bag, air is blown into the bag and  
the bag is tied off. This is the most common method used for solar panel cookers, such as the Solar CooKit,  
because of the bags’ ability to withstand the temperatures attained in these types of cookers. But these bags  
tear rather easily and they are not readily available in developing countries and must be imported.

The second method of closing off the cooking vessel from convection currents, designed by Dr. Jones, is to  
place a clear plastic disk down into the funnel above the cooking vessel. The funnel used in the test was a  
conventional-shaped funnel that was constructed out of thin sheet metal and aluminium-foil lined for better  
reflectivity. The diameter of this funnel is about 30 inches at the top, and it stands about 16 inches high.  
The walls also form about a 60 degree angle with respect to the horizontal. This funnel was designed to hold  
a larger cooking container such as a pot. The diameter of the plastic disk is large enough that the disk does  
not touch the top of the container. For the experiments that tested this method, a one-sixteenth inch (1.6  
mm) thick Lexan disk was used.

Data Collection  
To collect the temperatures as a function of time, a Texas Instruments Calculator Based Laboratory (CBL)  
was used. This portable interface is capable of recording real-time data from multiple channels. The data  
were downloaded into a graphing calculator, where they can be analysed and graphed immediately. From  
the calculator, the data can be transferred to a computer spreadsheet such as Microsoft Excel for further  
analysis. Due to the nature of these experiments and the low cost to purchase the CBL, this is an ideal data  
collector to use. A graphing calculator was used to program the CBL and to tell it what data to collect, how  
many points to collect, and the time period between data points collected. Since the CBL does not have any  
internal programs for data collection, a program must be written into the graphing calculator. There are  
ready-made programs that can be uploaded into the calculator, or a custom program can be made to fit the  
needs of the test. The program that the CBL used allowed multiple thermocouples to collect data  
simultaneously. To ensure that the thermocouples were calibrated against each other, both were run on the  
same constant temperature sample in very close proximity. Both temperature probes agreed to within 0.21OC  
of each other. For these experiments, this temperature difference was considered to be acceptable.