---
canonical: "https://yogababe.online/reading/BATCH2-006/804"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 804 · 14 - 44 | Rejuvenati"
content_sha256: "534832a163714d7924cc78bfb304a4ea7f380473ff7b3e5fa0c582ca98c1cec9"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 784 · section 804/1965 · approximately 4 minutes

## 14 - 44

14 - 44  
How can one readily determine if the water from a well, pump, stream, etc. is safe to drink? The common  
procedure is to test the water for bacterial indicators of faecal pollution. There are two groups of  
indicators which are used. The first is the coliform bacteria which are used as indicators in developed  
countries where water is chlorinated. Coliform bacteria may come from faeces or from plants. Among  
the coliform bacteria is the second indicator, Escherichia coli. This bacterium is present in large numbers  
in human faeces (approximately 100,000,000 per gram of faeces) and that of other mammals. This is the  
main indicator used if water is not chlorinated. A water source containing 100 E. coli per 100 ccs poses  
a substantial risk of disease.

The standard method of testing water for the presence of coliforms and E. coli requires trained personnel  
and a good laboratory facility or field unit which are usually not present in developing countries. Thus,  
water supplies are almost never tested.

A new approach to testing in developing countries  
In 1987, the Colilert MPM Test (CLT) was introduced as the first method which used a defined substrate  
technology to simultaneously detect coliforms and E. coli. The CLT comes as dry chemicals in test tubes  
containing two indicator nutrients: one for coliforms and one for E. coli. The CLT involves adding 10 ml  
of water to a tube, shaking to dissolve the chemicals, and incubating at body temperature for 24 hours. I  
prefer incubating tubes under my belt against my body. At night I sleep on my back and use night  
clothes to hold the tubes against my body.

If no coliform bacteria are present, the water will remain clear. However, if one or more coliforms are  
present in the water, after 24 hours their growth will metabolise ONPG and the water will change in colour  
from clear to yellow (resembling urine). If E. coli is among the coliform bacteria present, it will metabolise  
MUG and the tube will fluoresce blue when a battery-operated, long-wave ultraviolet light shines on it,  
indicating a serious health hazard. I have invited participants at solar box cooker workshops in Sierra  
Leone, Mali, Mauritania, and Nepal to test their home water supplies with CLT. One hundred and twenty  
participants brought in samples. In all four countries, whether the water was from urban or rural areas,  
the majority of samples contained coliforms, and at least half of these had E. coli present. Bacteriological  
testing of the ONPG and MUG positive tubes brought back from Mali and Mauritania verified the  
presence of coliforms/E. coli in approximately 95% of the samples. It is likely that soon the Colilert MPN  
test will be modified so that the test for E. coli will not require an ultraviolet light, and the tube will turn a  
different colour than yellow if E coli is present. This will make the test less expensive and easier to widely  
use in developing countries to assess water sources.

Effect of safe water on diarrhoea in children  
What would be the effect if contaminated water could be made safe for drinking by pasteurisation or  
boiling? One estimate predicts that if in the Philippines, families at present using moderately  
contaminated wells (100 E. coli per 100 ml) were able to use a high-quality water source, diarrhoea  
among their children would be reduced by over 30%. Thus, if water which caused a MUG (+) test were  
solar pasteurised so it would be clear, this would help reduce the chance of diarrhoea, especially in  
children.

Water pasteurisation indicator

How can one determine if heated water has reached 65O C? In 1988, Dr. Fred Barrett (USDA, retired)  
developed the prototype for the Water Pasteurisation Indicator (WAPI). In 1992, Dale Andreatta, a  
graduate engineering student at the University of California, Berkeley, developed the current WAPI. The  
WAPI is a polycarbonate tube, sealed at both ends, partially filled with a soybean fat which melts at 69O C

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-006-S00804)

---
[Native HTML](https://yogababe.online/reading/BATCH2-006/804) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
