IDEXX Laboratories, Inc. makes the Colilert kit and is located at this address:
IDEXX Laboratories, Inc.
One IDEXX Drive
Westbrook, ME 04092
USA
Voice: [personal contact detail redacted] or [personal contact detail redacted]
Fax: [personal contact detail redacted]
Editor's Note: Testing Water in Developing Countries
The Colilert system makes it possible to test water without the need for a laboratory. IDEXX Laboratories,
the manufacturer, recommends that you use five test tubes for each sample. Bob Metcalf explains that
five tubes would comprise 50 ml, which is the minimum sample size permitted by US law. This is an
unrealistically high standard by which to judge the water in developing countries where you are examining
water that is already being drunk, in spite of the fact that it may be making people sick. By using a single
test tube (10 ml) there is a very small chance that your sample missed the small number of bacteria that
might have been present.
IDEXX Laboratories will also tell you that you need an incubator to achieve valid results. Again, Bob
Metcalf tells us that all that is needed is to keep the tubes close to your body for 36 hours, since body
temperature is the correct incubation temperature.
What you are actually measuring in the test is the presence of 1) coliform bacteria, and 2) E. coli, a type
of coliform bacteria that is largely found in faecal matter. A positive test for coliform bacteria might be due
to coliform bacteria that has washed off of plant leaves , and thus be fairly innocuous. A positive test for
E. coli, however, would indicate that any bacteriological contamination was from a faecal source, which
might also contain Giardia, cholera, or other serious infectious microbes.
This document is published on The Solar Cooking Archive at
http://solarcooking.org/pasteurisation/metcalf.htm.
The Solar Puddle
A new water pasteurisation technique for large amounts of water
The lack of clean drinking water is a major health problem in the developing world. To reduce this health
risk ways of producing clean water at an affordable cost are needed, and people need to be educated
about germs and sanitation, lest they accidentally re-contaminate their clean drinking water. Recently,
several of us at the University of California at Berkeley have attacked the first of these requirements.
Previous issues of this newsletter have included stories about our water pasteurisation indicator and our
flow-through water pasteurises based on a design by PAX World Service. In this article we describe a
new low-cost device that pasteurises water.
For those not familiar with the pasteurisation process, if water is heated to 149O F (65O C) for about 6
minutes all the germs, viruses, and parasites that cause disease in humans are killed, including cholera
and hepatitis A and B. [Ed. We have reports from the field that at 145O F (63O C) in a solar puddle,
bacterial growth might actually be increased. Since this temperature is very close to the minimum
pasteurisation temperature mentioned in this article, we suggest that you heat the water to a higher
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.