Wire Sizes:
The wire sizes specified for use in some designs are American Wire Gauge so a comparison table showing the
UK Standard Wire Gauge and the American Wire Gauge is given here:
AWG
Dia mm
Area
mm2
SWG
Dia mm
Area
mm2
Max
Amps
Ohms /
metre
Max
Hz
1
7.35
42.40
2
7.01
38.60
119
325
2
6.54
33.60
3
6.40
32.18
94
410
3
5.88
27.15
4
5.89
27.27
75
500
4
5.19
21.20
6
4.88
18.68
60
650
5
4.62
16.80
7
4.47
15.70
47
810
6
4.11
13.30
8
4.06
12.97
37
1,100
7
3.67
10.60
9
3.66
10.51
30
1,300
8
3.26
8.35
10
3.25
8.30
24
1,650
9
2.91
6.62
11
2.95
6.82
19
2,050
10
2.59
5.27
12
2.64
5.48
15
0.0042
2,600
11
2.30
4.15
13
2.34
4.29
12
0.0053
3,200
12
2.05
3.31
14
2.03
3.24
9.3
0.0067
4,150
13
1.83
2.63
15
1.83
2.63
7.4
0.0085
5,300
14
1.63
2.08
16
1.63
2.08
5.9
0.0107
6,700
15
1.45
1.65
17
1.42
1.59
4.7
0.0135
8,250
16
1.29
1.31
18
1.219
1.17
3.7
0.0170
11 kHz
17
1.15
1.04
2.9
0.0214
13 kHz
18
1.024
0.823
19
1.016
0.811
2.3
0.027
17 kHz
19
0.912
0.653
20
0.914
0.657
1.8
0.034
21 kHz
20
0.812
0.519
21
0.813
0.519
1.5
0.043
27 kHz
21
0.723
0.412
22
0.711
0.397
1.2
0.054
33 kHz
22
0.644
0.325
23
0.610
0.292
0.92
0.069
42 kHz
23
0.573
0.259
24
0.559
0.245
0.729
0.086
53 kHz
24
0.511
0.205
25
0.508
0.203
0.577
0.109
68 kHz
25
0.455
0.163
26
0.457
0.164
0.457
0.137
85 kHz
26
0.405
0.128
27
0.417
0.136
0.361
0.174
107 kHz
27
0.361
0.102
28
0.376
0.111
0.288
0.218
130 kHz
28
0.321
0.0804
30
0.315
0.0779
0.226
0.276
170 kHz
29
0.286
0.0646
32
0.274
0.0591
0.182
0.344
210 kHz
30
0.255
0.0503
33
0.254
0.0506
0.142
0.439
270 kHz
31
0.226
0.0401
34
0.234
0.0428
0.113
0.554
340 kHz
32
0.203
0.0324
36
0.193
0.0293
0.091
0.685
430 kHz
33
0.180
0.0255
37
0.173
0.0234
0.072
0.870
540 kHz
34
0.160
0.0201
38
0.152
0.0182
0.056
1.105
690 kHz
35
0.142
0.0159
39
0.132
0.0137
0.044
1.398
870 kHz
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide