Skip to contentREJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITYTranslated introduction guidesTranslate this page without leaving it. First-time translations use the owner's local computer and are then cached for everyone; uncached translations may be unavailable while that helper is offline. Automatic translation may contain errors. Scientific identifiers and numeric data stay unchanged. Verify medical information against the original source.
science · SOURCE BATCH2-006
A Practical Guide to Free-Energy Devices — Patrick J. Kelly
attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.
Source page 877 · section 896/1965 · approximately 1 minutes
A - 31
A - 31
Referring now to Fig.6, Fig.7D and Fig.8E there is shown a seventh preferred embodiment of the motor 10. The structure and operation of the seventh preferred embodiment is similar to the sixth preferred embodiment except that the third stator magnet 41' located on the surface 64 of the stator 51'' along the line of demarcation 49 is a U- shaped magnet 41' with the rear of the U-shaped magnet 41' facing the rotor 12 and the direction of magnetisation being perpendicular to the line of demarcation 49; and the U-shaped magnet 20 is replaced with a bar magnet 20' oriented to have the direction of magnetisation aligned with a radial line of the rotor 12. As in the sixth preferred embodiment, each stator magnet 40', 42' could be a U-shaped magnet or could be made up of separate magnets, as long as the first magnetic field generated by the stator magnets 40', 42' was generally equivalent to that produced by the bar magnets.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.