canonical: "https://yogababe.online/reading/BATCH2-006/937"
language: "en"
title: "A Practical Guide to Free-Energy Devices — Patrick J. Kelly · section 937 · A - 67 | Rejuvenati"
content_sha256: "d21934a8c981f68475439779dc5b297a2726a89ad81e735f0c54870d344fcaaf"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-006

# A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

[Open first-party PDF viewer](https://yogababe.online/pdf/BATCH2-006)

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

[Contents and coverage](https://yogababe.online/reading/BATCH2-006) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=A) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-006)

## Synopsis

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

## Executive summary

### A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide](https://yogababe.online/packet/P-BATCH2-006)

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-006)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 913 · section 937/1965 · approximately 2 minutes

## A - 67

A - 67  
the magnetic field. An examination of magnetic field patterns is therefore essential to an understanding of  
generator operation.

In generator 10, magnetic flux emanating from the north poles of carousel magnets 25A and 25B pass through  
the rotor magnets and then return to the south poles of the carousel magnets. The total flux field is thus driven by  
the combined MMF (magnetomotive force) of the carousel and field magnets while the flux patterns are  
determined by the orientation of the rotor and carousel magnets.

The flux pattern between carousel magnets 25A and 25B and the upper and lower rotor magnets 21 and 22 is  
illustrated in Fig.4. Magnetic flux lines 31 from the north pole of carousel magnet 25A extend to the south pole of  
upper rotor magnet 21, pass through magnet 21 and return as lines 31' to the south pole of magnet 25A. Lines  
33, also from the north pole of magnet 25A extend to the south pole of lower rotor magnet 22, pass through  
magnet 22 and return to the south pole of magnet 25A as lines 33'. Similarly, lines 32 and 34 from the north pole  
of magnet 25B pass through magnets 21 and 22, respectively, and return as lines 32' and 34' to the south pole of  
magnet 25B. Flux linkages produced in coil 17 by lines emanating from carousel magnet 25A are of opposite  
sense from those emanating from carousel magnet 25B. Because induced voltage is a function of the rate of  
change in net flux linkages, it is important to recognise this difference in sense.