Source page 925 · section 949/1965 · approximately 2 minutes
A - 79
A - 79
Table 1 shows the data to be obtained relating to the optical electrostatic generator. Table 2 shows the lamp
performance and efficiency for each of the tests shown in Table 1. The following is a description of the data in
each of the columns of Tables 1 and 2.
Column
Description
B
Gas used in discharge tube
C
Gas pressure in tube (in torrs)
D
Field strength across the tube (measured in volts per cm. of length between the electrodes)
E
Current density (measured in microamps per sq. mm. of tube cross-sectional area)
F
Current (measured in amps)
G
Power across the tube (calculated in watts per cm. of length between the electrodes)
H
Voltage per lamp (measured in volts)
K
Current (measured in amps)
L
Resistance (calculated in ohms)
M
Input power per lamp (calculated in watts)
N
Light output (measured in lumens)
Table 1
Optical
Generator
Section
A
B
C
D
E
F
G
Test No.
Type of
discharge
lamp
Pressure of
Xenon
Field
strength
across lamp
Current
density
Current
Power str.
across lamp
(Torr)
(V/cm)
(A/sq.mm)
(A)
(W/cm.)
1
Mo elec
-
-
-
-
-
2
Xe
0.01
11.8
353
0.1818
2.14
3
Xe
0.10
19.6
353
0.1818
3.57
4
Xe
1.00
31.4
353
0.1818
5.72
5
Xe
10.00
47.2
353
0.1818
8.58
6
Xe
20.00
55.1
353
0.1818
10.02
7
Xe
30.00
62.9
353
0.1818
11.45
8
Xe
40.00
66.9
353
0.1818
12.16
9
Xe
60.00
70.8
353
0.1818
12.88
10
Xe
80.00
76.7
353
0.1818
13.95
11
Xe
100.00
78.7
353
0.1818
14.31
12
Xe
200.00
90.5
353
0.1818
16.46
13
Xe
300.00
100.4
353
0.1818
18.25
14
Xe
400.00
106.3
353
0.1818
19.32
15
Xe
500.00
110.2
353
0.1818
20.04
16
Xe
600.00
118.1
353
0.1818
21.47
17
Xe
700.00
120.0
353
0.1818
21.83
18
Xe
800.00
122.8
353
0.1818
22.33
19
Xe
900.00
125.9
353
0.1818
22.90
20
Xe
1,000.00
127.9
353
0.1818
23.26
21
Xe
2,000.00
149.6
353
0.1818
27.19
22
Xe
3,000.00
161.4
353
0.1818
29.35
23
Xe
4,000.00
173.2
353
0.1818
31.49
24
Xe
5,000.00
179.1
353
0.1818
32.56
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.