A - 98
A - 98
Table 1
50% Electricity Used
100% Electricity Used
Type of Generator
Electricity Output
(Watts)
Amount of Load
(Watts)
Electricity Output
(Watts)
Amount of Load
(Watts)
Conventional:
100
221
14
347
This invention:
100
220
183
200
(electricity output and load amount of the alternating current generators when 50% and 100% of the electricity
were used)
From the result of Experimental Example 1 above, the reason for the remarkable reduction of the electricity output
when the electricity consumption was 100% relative to the electricity consumption of 50% in the conventional
generator is considered to be the significant increase of the repulsive load exerted on the generator when 100%
of the electricity is used.
On the other hand, in the generator of the present invention, there was no appreciable difference in the amount of
load between those cases in which 50% of the electricity was used and 100% thereof was used respectively.
Rather, the amount of load slightly decreased (approximately 20W) when 100% of the electricity was used. In
view of this, it can be understood that the amount of generated electric power of the generator of the present
invention is approximately doubled as the electricity consumption increases, which is different from the
conventional generator producing electric power which sharply decreases when the electricity consumption
increases.
In conclusion, the amount of load above is supposed to be numerical value relative to the mechanical load of the
generator as described above. Any secondary load except this, i.e. load due to the reverse currents generated in
the armature responsive coils can be confirmed as zero.
EXPERIMENTAL EXAMPLE 3
12V direct current (DC) generators having similar conditions to those in experimental example 1 were used to
make measurement under the same conditions (efficiency 80%). The result of the measurement is presented
below.
Table 2
50% Electricity Used
100% Electricity Used
Type of Generator
Electricity Output
(Watts)
Amount of Load
(Watts)
Electricity Output
(Watts)
Amount of Load
(Watts)
Conventional:
103
290
21
298
This invention:
107
282
236
272
(electricity output and load amount of the alternating current generators when 50% and 100% of the electricity
were used)
The DC generator has higher efficiency (80%) than that of the AC generator, while use of the brush increases the
cost of the DC generator. When 100% of the electricity was used, the amount of load slightly decreased which
was similar to the result shown in Table 1 and the electricity output was approximately at least 2.2 times that when
50% of the electricity was used.
EXPERIMENTAL EXAMPLE 4
A 220V single-phase alternating current (AC) generator (0.5HP) having similar conditions to those in experimental
example 1 was used, and the rotation per minute (rpm) was changed to make measurement under the condition
of 100% consumption of the generated electricity. The result of measurement is illustrated in the following Table
3.
Table 3
1750
rpm
3600
rpm
5100
rpm
Electricity
Output
(Watts)
Amount of
Load
(Watts)
Electricity
Output
(Watts)
Amount of
Load
(Watts)
Electricity
Output
(Watts)
Amount of
Load
(Watts)
130
160
210
228
307
342
(amounts of generated electric power and load when the rotation per minute of the generator of the present
invention was varied)
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.