Source page 964 · section 991/1965 · approximately 4 minutes
A - 118
A - 118
balance of the preferred composition is selenium although it has also been found that nominal impurity levels can
be tolerated and no great care is required in preventing minor contamination.
The other selenium base composition useful in practice of this invention can have a tellurium concentration in the
range of from about 4.85% to 5.5% by weight, germanium in the range of from about 3.95% to 4.2% by weight,
neodymium in the range of from about 2.85% to 3.2% by weight, and gallium in the range of from about 2.0% to
2.5% by weight. As in the preferred composition, the balance is selenium and nominal impurity levels can be
tolerated. It is preferred to add the gallium in the form of gallium selenide rather than as elemental gallium with a
corresponding decrease in the selenium used to make up the composition.
The above selenium base compositions are easier to make and less expensive than the germanium base
composition and are therefore preferable for most applications. It is found that these are particularly suited for
relatively small semiconductor tablets up to about 1 inch or a little less. For relatively large tablets, it is preferred
to use the germanium base composition.
The germanium base composition has a tellurium level in the range of from about 4.75% to 5.5% by weight,
neodymium in the range of from about 4.0% to 4.5% by weight, and rubidium in the range of from about 5.5% to
7.4% by weight. It is also found that it is of greater importance to maintain purity of the germanium base
compositions than the selenium base compositions. Although the exact purity levels have not been ascertained, it
is in excess of 99%.
It has been found that it is not necessary to have single crystals in the semiconductor tablets and any convenient
grain size in excess of about 1 millimetre appears satisfactory. In the above compositions, when the recited
ranges are exceeded, oscillation in the power pack drops off rapidly and may cease altogether.
The reasons that these compositions are satisfactory in the arrangement providing resonance amplification has
not been determined with certainty. It is possible that the semiconductor serves as a source of electrons for
providing an oscillating current in the circuit. This is, of course, combined with a relatively large area contact to
one side of the semiconductor tablet, and a point contact on another area. Any resonant current in the coils
wound on the ferrite rod, induces a varying magnetic field in the resonant cavity, and the electrical connection
between the ferrite rod and the metal probe, provides a feedback of this oscillation to the semiconductor tablet.
it should particularly be noted that the oscillation in the circuit does not commence until it is initiated by an
oscillating signal. In order to accomplish this, it is only necessary to apply a few millivolts of AC for a few seconds
to the semiconductor tablet and the associated coils coupled to it. The initial signal applied to the base of the
semiconductor tablet and the lead 39 is preferably in the frequency range of 5.8 to 18 Mhz and can be as high as
150 Mhz. Such a signal can be applied from any conventional source and no great care appears necessary to
provide a single frequency signal or to eliminate noise. Once such energisation has been applied to the circuit
and oscillations initiated, it does not appear to be necessary to apply such a signal again. This is apparently due
to the feedback provided by the ferrite rod to the probe which makes contact with the semiconductor tablet.
Energy is, of course, dissipated in the lamp, or other utilisation device, as the combination operates. Such energy
may come from deterioration of the semiconductor tablet as oscillations continue; however, if there is any such
deterioration, it is sufficiently slow that a power source may be operated for many months without attendance.
Such a source of energy may be augmented by ambient Radio Frequency radiation, coupled into the resonant
cavity by the external leads. This is a surprising phenomenon because the leads are small compared to what
would normally be considered an adequate antenna, and it is therefore postulated that stimulated amplification
may also be a consequence of the unique electronic configuration of the semiconductors having the compositions
specified above.
Although only one embodiment of electric power pack constructed according to principles of this invention has
been described and illustrated here, many modifications and variations will be apparent to one skilled in the art.
Thus, for example, a larger power pack may be axially arranged in a cylindrical container with various electronic
elements arranged in the annular space. It is therefore to be understood that other configurations are included
within the scope of the invention.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.