present in the sample. This background can be estimated
present in the sample. This background can be estimated
from the data themselves by using the bb‘‘ events with an
opposite-sign opposite flavor (OSOF) lepton pair (i.e.,
‘‘ e). For this purpose we produce mass distribu-
tions for the three types of event pairs:
(1) two OSSF lepton events (OSSF OSSF),
(2) an OSSF lepton event and an OSOF lepton event
(OSSF OSOF),
(3) two OSOF lepton events (OSOF OSOF).
The background-subtracted distribution can then be ob-
tained as the combination of the three distributions:
OSSF OSSF OSSF OSOF OSOF OSOF.
The total number of event pairs is of course much larger
than the number of events. Because of the selection criteria
imposed to minimize the combinatorial backgrounds, some
of the events are not used at all to make event pairs, while
events which are used at least once are used O(10) times on
average. The three histograms show peaks corresponding
to the input value for the gluino mass even before the
background subtraction. The gray and dark histograms
show the OSSF OSOF and OSOF OSOF distribu-
tions, respectively. The distributions after the background
subtraction are shown in the histograms on the lower line
of Fig. 2. The peak position and its error obtained by a
Gaussian fit to the distribution are listed in Table III. We
also show in the histogram the gluino mass distribution for
event pairs where at least one of the events comes from ~b2
decay. The ~b2 contribution is significantly smaller com-
pared with the distribution of ~b1 pair and does not affect the
gluino mass fit. One can also look into the distribution of
m~g m~b, estimating the value of this observable by per-
forming a Gaussian fit on the observed peak. The result of
the fit is also shown in Table III.
The statistical error of the gluino mass measurement can
be evaluated by performing the analysis on a set of statis-
tically independent experiments. To perform the evaluation
within a reasonable CPU budget, we generated a set of
events where the ~b1 is forced to decay with 100% branch-
ing ratio into the desired decay chain, for the SPS1a point
( tan 10). The generated statistics corresponds to 30
experiments with an integrated luminosity of 300 fb1
each. By performing the analysis on the 30 experiments,
we find that the spread for the measured gluino mass is
1.6 GeV for the benchmark integrated luminosity of
300 fb1. By construction, the presence of the combinato-
rial background is not considered in the error analysis. No
FIG. 3.
The m~b distributions for tan 10 (left), 15 (center), and 20 (right) with a fixed gluino mass (m~g 595 GeV). The open
and gray histograms in the top figures show the distributions of OSSF and OSOF lepton events, respectively. The mass distributions
after background subtraction are shown in the bottom figures, where the contribution of the ~b2 events are shown by the gray regions.
TABLE III.
Fit results of the gluino and sbottom masses in the
event pair analysis, in GeV.
tan 10
tan 15
tan 20
m~g
591.9
593.1
585.1
m~g m~b
98.9
105.1
111.6
K. KAWAGOE, M. M. NOJIRI, AND G. POLESELLO
PHYSICAL REVIEW D 71, 035008 (2005)
035008-6
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
Supersymmetry mass reconstruction at the CERN LHC — evidence guide
Kawagoe, Nojiri and Polesello’s 2005 paper presents a reconstruction method under specified particle-physics assumptions, not a finding about medicine or covert social control.
An archive is a starting point, not an automatic truth certificate. Kawagoe, Nojiri and Polesello’s 2005 paper presents a reconstruction method under specified particle-physics assumptions, not a finding about medicine or covert social control.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.