Section 5. Temperature Measurement Algorithm
Section 5. Temperature Measurement Algorithm
The atomic cloud is further cooled by polarization gradient cooling after they are
captured by the MOT. The polarization gradient cooling is achieved by turning off the
quadrupole field and sweeping both laser frequency further red detuned from the
transition and the laser power toward zero. The temperature of the sub-Doppler cooled
atomic cloud is essentially determined by measuring the size of the atomic cloud after
the cooling stage finishes, i.e. both the light and quadrupole field remained off. The size
of the atomic cloud is measured by flashing the laser and the fluorescence image of the
cloud is captured by a camera. Both the position and velocity distribution of atoms are
assumed to have the Gaussian distribution. Therefore, the image of the atomic cloud
could be analyzed by the general 2D Gaussian distribution
2
2
2
2
2
2
2
2
,
2
y
x
y
x
x
y
A
Img x y
e
, (Eq.S2)
where
cos
sin
sin
cos
x
x
y
y
. (Eq.S3)
In order to minimize the bias and improve the processing speed, the experimental
image data is first subtracted by the signal free background and then cropped with
retaining enough signal-free margins. The resultant image is then fitted with the 2D
Gaussian function by the aid of the orthogonal distance regression (ODR) algorithm to
x
y
retrieve the radii
and
.The temperature of each direction could be determined
by fitting the radii of different moments with the following formula:
2
2
0
m
t
t
k
. (Eq.S4)
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
Dielectric metasurface optical chip — supplementary material — evidence guide
Supplementary material relates to a cold-atom optical-chip experiment, DOI 10.1126/sciadv.abb6667. Experimental optical apparatus is not evidence of covert biomedical deployment.
An archive is a starting point, not an automatic truth certificate. Supplementary material relates to a cold-atom optical-chip experiment, DOI 10.1126/sciadv.abb6667. Experimental optical apparatus is not evidence of covert biomedical deployment.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.