---
canonical: "https://yogababe.online/reading/BATCH2-024/6"
language: "en"
title: "Dielectric metasurface optical chip — supplementary material · section 6 · Section 2. Fundamentals of MOT | Rejuvenati"
content_sha256: "3e08ed7151f3ed1c33eb6ead9b5832e79516649388f1664dd800cb5d7dc63eb5"
source: "Same native server-rendered main content; interface controls omitted"
---

science · SOURCE BATCH2-024

# Dielectric metasurface optical chip — supplementary material

attributed reading edition with marked omissions · 14 source pages · 14 native web sections · 2,681 published words

Public source trail: [Research DOI](https://doi.org/10.1126/sciadv.abb6667)

[Contents and coverage](https://yogababe.online/reading/BATCH2-024) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=Dielectric) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-024)

## Synopsis

Supplementary material relates to a cold-atom optical-chip experiment, DOI 10.1126/sciadv.abb6667. Experimental optical apparatus is not evidence of covert biomedical deployment.

## Executive summary

### Dielectric metasurface optical chip — supplementary material — evidence guide

Supplementary material relates to a cold-atom optical-chip experiment, DOI 10.1126/sciadv.abb6667. Experimental optical apparatus is not evidence of covert biomedical deployment.

An archive is a starting point, not an automatic truth certificate. Supplementary material relates to a cold-atom optical-chip experiment, DOI 10.1126/sciadv.abb6667. Experimental optical apparatus is not evidence of covert biomedical deployment.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [Dielectric metasurface optical chip — supplementary material — evidence guide](https://yogababe.online/packet/P-BATCH2-024)

Supplementary material relates to a cold-atom optical-chip experiment, DOI 10.1126/sciadv.abb6667. Experimental optical apparatus is not evidence of covert biomedical deployment.

An archive is a starting point, not an automatic truth certificate. Supplementary material relates to a cold-atom optical-chip experiment, DOI 10.1126/sciadv.abb6667. Experimental optical apparatus is not evidence of covert biomedical deployment.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-024)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 6 · section 6/14 · approximately 3 minutes

## Section 2. Fundamentals of MOT

Section 2. Fundamentals of MOT  
The basic concept of magneto-optical trapping (MOT) is introduced in this section  
while details can be found in (31). As atoms moving along one direction are illuminated  
by a pair of counter-propagating laser beams (Fig. S4A) with the frequencies slightly  
below the atomic resonance, they are more likely to absorb photons of the beam from  
the opposite direction because of Doppler shift. Subsequently the atoms spontaneously  
re-emit photons into random directions. After many cycles, the atoms acquire  
momentum kicks from the opposite direction and the net recoil momentum from the  
emissions is essentially zero because of the randomness of the emission direction. The  
whole optical process is equivalent to providing a spatially independent damping force.  
As illustrated in Fig. S4B, a spatially dependent force for trapping atoms can be created  
by adding a quadrupole magnetic field generated by a pair of anti-Helmholtz coils.  
Depending on their magnetic quantum numbers, the energies of different Zeeman  
sublevels are shifted differently by the quadrupole field. Considering an atom displaced  
from the center of the trap along the z-axis with z > 0, so the mj = -1 and +1 sublevels  
are respectively shifted towards and away from the laser frequency. Assuming both  
beams are right circularly polarized, the left and right beams respectively drive 𝜎+and  
𝜎− transitions in respect of the local magnetic field, i.e. the quantization axis.  
Consequently, the atom will absorb more photons from the right beam than the left one.  
Equivalently the atom is experiencing a larger force as it is away from the center  
because of the increase of the absorption imbalance between two beams. Fig. S4C  
illustrates a three-dimensional MOT which is an extension of aforementioned 1D  
concept. It is worth to note that the handedness of laser beams on the radial direction is  
opposite to the one on the axial direction because of opposite field directions on the  
radial and the axial directions. Atoms entering the intersection region of the laser beams  
are slowed, and the position-dependent forces push the cold atoms to the trap center.  
The simplicity and robustness of MOT make it be widely used in cold atom  
experiments.  
Fig. S4D shows our experimental configuration of the MOT with metasurface  
optical chip. The laser beam after the metasurface is converted to the opposite circular  
polarization, from left-hand circular polarization (LCP) to right circular polarization  
(RCP) in the experiment. Then the four diffracted beams are reflected by four mirrors,  
which change the polarizations to LCP while the retro-reflected central beam maintains  
the RCP after passing through a quarter-wave plate twice. It is worth mentioning that  
the MOT functions by reversing both the handedness of laser pairs and coil current  
direction.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-024-S00006)

---
[Native HTML](https://yogababe.online/reading/BATCH2-024/6) · [Sources and rights](https://yogababe.online/sources) · [Editorial standards](https://yogababe.online/terms) · [Multilingual record access](https://yogababe.online/api/i18n/catalog)
