# VeriChip H2 RFID reader — operator manual

attributed reading edition with marked omissions · 11 source pages · 11 native web sections · 4,346 published words

[Contents and coverage](https://yogababe.online/reading/BATCH2-037) · [All reading editions](https://yogababe.online/library) · [Explanatory guides](https://yogababe.online/packets?q=VeriChip) · [Source metadata](https://yogababe.online/api/reading/documents/BATCH2-037)

## Synopsis

The manual describes a low-frequency reader receiving a 16-digit identifier from a transponder. Identification technology and consent-based database access are distinct from claims of mind reading.

## Executive summary

### VeriChip H2 RFID reader — operator manual — evidence guide

The manual describes a low-frequency reader receiving a 16-digit identifier from a transponder. Identification technology and consent-based database access are distinct from claims of mind reading.

An archive is a starting point, not an automatic truth certificate. The manual describes a low-frequency reader receiving a 16-digit identifier from a transponder. Identification technology and consent-based database access are distinct from claims of mind reading.

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

**Attributed source text—not an independently verified finding.**

This is a reading edition of an supplied source document. Its allegations, confidence labels, legal interpretations, scientific claims and assertions of authority belong to the source author. Inclusion establishes neither guilt nor clinical efficacy, treaty adoption, sovereign recognition or financial authorization. Source references are leads for checking, not automatic corroboration. [How to read an allegation](https://yogababe.online/articles/reading-evidence) · [Editorial standards and corrections](https://yogababe.online/terms)

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

### [VeriChip H2 RFID reader — operator manual — evidence guide](https://yogababe.online/packet/P-BATCH2-037)

The manual describes a low-frequency reader receiving a 16-digit identifier from a transponder. Identification technology and consent-based database access are distinct from claims of mind reading.

An archive is a starting point, not an automatic truth certificate. The manual describes a low-frequency reader receiving a 16-digit identifier from a transponder. Identification technology and consent-based database access are distinct from claims of mind reading.

[Full commentary and investigation questions](https://yogababe.online/packet/P-BATCH2-037)

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 9 · section 9/11 · approximately 2 minutes

## 16

16  
15  
Table 206: Recommended separation distances between  
portable and mobile RF communications equipment and the  
VeriMed reader.  
The VeriChip H2 Reader is intended for use in an electromagnetic  
environment in which radiated RF disturbances are controlled.  
The customer or the user of the VeriChip H2 Reader can help prevent  
electromagnetic interference by maintaining a minimum distance  
between portable and mobile RF communications equipment  
(transmitters) and the VeriChip H2 Reader as recommended below,  
according to the maximum output power of the communications  
equipment.  
Rated  
maximum  
output  
power of  
transmitter  
Separation distance according to frequency  
of transmitter  
150 KHz to 80  
MHz  
80 MHz to  
800 MHz  
800 MHz to  
2.5 GHz  
W  
Not applicable,  
per IEC 61000-  
4-6  
“Conducted RF”  
since no power  
cords or cables  
are used with  
the Reader.  
d = 1.2 √P  
d = 2.3 √P  
0.01  
0.12  
0.23  
0.1  
0.38  
0.73  
1  
1.2  
2.3  
10  
3.8  
7.3  
100  
12  
23  
For transmitters rated at a maximum output power not listed  
above, the recommended separation distance d in meters (m) can  
be estimated using the equation applicable to the frequency of the  
transmitter, where P is the maximum output power rating of the  
transmitter in watts (W) according to the transmitter manufacturer.  
NOTE 1: At 80 MHz and 800 MHz, the separation distance for  
the higher frequency range applies.  
NOTE 2: These guidelines may not apply in all situations.  
Electromagnetic propagation is affected by absorption and  
reflection from structures, objects and people.  
Operating Frequency  
134.2 KHz  
Frequency Modulation Type  
Amplitude Shift Keying (ASK)  
Modulation  
Bandwidth  
± 4KHz  
Effective Radiated Power  
0.185mW  
Radiated Output at 10 meters 28.1 dBuA/m  
Case Size  
178mm L x 82mm W x 32mm H  
Weight  
300g +/- 10g (w/o batteries)  
Material  
PC/ABS blend Plastic  
Operating Temperature &  
Humidity  
32°F to 122°F (0°C to 50°C) and  
a maximum relative humidity  
of 90%, noncondensing  
Storage Temperature &  
Humidity  
\-4°F to 140°F (-20°C to 60°C)  
and a maximum relative  
humidity of 90%, non-  
condensing  
Batteries  
Quantity 4-AA  
Alkaline Batteries  
Display  
LCD 32-character, 2 line,  
backlit  
Range  
2.5” when optimum  
conditions are met. No  
external interference, no  
metal near transponder or  
reader and new batteries  
Physical and Electronic Characteristics  
Sterility: Non-sterile. Do not sterilize.  
Usage: Multiuse, battery dependent.

[This full section as JSON](https://yogababe.online/api/reading/sections/BATCH2-037-S00009)

---