Source page 6 · section 6/11 · approximately 3 minutes
International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May-2015
International Journal of Scientific & Engineering Research, Volume 6, Issue 5, May-2015 352
ISSN 2229-5518
IJSER © 2015
http://www.ijser.org
Sensing temperature is a key functionality of human skin that helps to prevent injury and provides
information about the surrounding environment, most tactile sensors are inherently temperature sensitive, and their
response must therefore be calibrated with a temperature sensor. Several groups have implemented piezoelectric
pyroelectric sensors that can discriminate between temperature and pressure inputs. Resistive temperature detectors
(RTD) are attractive for e-skin applications owing to their flexibility, simple device structure, and compatibility with
electronic readout methods.
RTDs relate a change in temperature to a corresponding resistance change through a material
commonly composed of metals such as Au and platinum (Pt). To deconvolute the contribution of tactile stimuli from
temperature sensors, meandering sections of Pt as temperature-sensing devices were implemented . These devices
achieved a resolution of 0.03 °C over a wide range of temperatures. stretchable temperature sensors based on thin,
buckled Au lines are also demonstrated .While the linear behavior of this sensor was attractive, the change in resistance
was relatively small, and would require a sensitive readout mechanism.
Self – Powering
Providing a long-lasting supply of power is a persistent challenge for mobile electronics. As the largest
human organ, skin provides a large area for potential energy storage. Furthermore, as the body’s interface with the
outside world, e-skins may provide the opportunity to scavenge energy from environmental sources such as light and
mechanical forces. A number of promising technologies have recently been demonstrated for power generation,
transmission, and storage in stretchable systems, including solar cells, mechanical energy harvesters, supercapacitors,
batteries, and wireless antennas.
Light is a readily available power source, and is most effectively harvested using devices with large
surface area. stretchable solar cells based on rigid GaAs device islands connected with freestanding metal interconnects
are determined . These solar cells operated with an efficiency of ≈13% with applied strain of up to 20%. Although these
devices provided exceptional performance, the high cost of GaAs may limit its implementation in large-area e-skins.
OPVs on ultrathin substrates using conventional materials and processes are fabricated . By transferring the devices to a
prestretched substrate, they were able to achieve a stretchability up to 400% with an efficiency of 4%.
Technologies for harnessing mechanical energy include both dielectric elastomer generators and
piezoelectric generators. Dielectric elastomer generators consist of an elastomeric dielectric coated with two highly
compliant electrodes, and their stretchability makes them attractive for use in e-skin. The electrodes are charged by
applying a voltage in the compressed state. Relaxation of the elastomer increases the voltage, producing higher energy
charges that are harvested. Dielectric elastomer generators can achieve very high efficiencies, but have historically been
limited by the complexity and weight of the associated electronics. Recent reports have demonstrated that the circuit
complexity can be reduced using systems that are self-primed or primed by electrets. Mechanical energy harvesting
devices based on nanostructured piezoelectric materials have also been developed, and stretchable versions have been
fabricated by buckling the active materials. Fueled by the development of new soft materials, the field of mechanically
compliant energy storage technologies has recently emerged.
Supercapacitors store energy in the form ofdouble layers of charged species residing at the electrode–
electrolyte interface and provide very high power densities. Buckled CNT electrodes on prestrained substrates have
been used to make supercapacitors that are stretchable up to 30%.
IJSER
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
Electronic Skin: A Brief Overview — M. S. Koushik — evidence guide
A 2015 overview describes electronic-skin research. A published overview is not a clinical approval, deployment inventory or proof of covert implants.
An archive is a starting point, not an automatic truth certificate. A 2015 overview describes electronic-skin research. A published overview is not a clinical approval, deployment inventory or proof of covert implants.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.