Source page 1432 · section 1501/1965 · approximately 4 minutes
A - 586
A - 586
Finally, an example of the correlation between the drive pack PAGD load voltage and the charge pack PAGD
charging voltage, as a function of the duration of the intervening PAGD run between resistive discharge
measurements, is shown in Fig.21, for the PAGD run corresponding to group 4 of Table 8.
Using the same pulse generator with H200 Al 128 cm2 plates, in a double diode configuration, and the same
circuit values (but with CP = 23 cells), three experiments were conducted at different PAGD frequencies, as a
function of varying air pressure. Analysis of driver pack losses and charge pack gains by the extensive load
discharge measurement method, as described before, led to the determination of the gross and net gains
(respectively, without and with losses included) per pulse, in milliwatt-hour, for each frequency, as well as of the
gross and net power gains per second of PAGD operation. The results are shown in Table 9. Even though the
gross and net gains of power per pulse were observed to increase with decreasing frequency, the gross power
gain per unit time increased with increasing frequency. However, this last trend does not necessarily translate
into a higher net gain per unit time, because the losses in the driver pack (not shown) also increase significantly
with PAGD frequency. These losses are in all probability related to more energy retention by the plasma at
higher frequencies when plasma extinction becomes incomplete. We expect net gains to reach optimal
thresholds for any given type of circuit configuration set of values and pulse generator dimensions.
Certain additional observations made during experiments with the double diode configuration of Fig.10A may
assist in understanding of the invention.
1) Replacing residual air with argon gas leads to higher PAGD frequencies, as noted by us when utilising a 128
cm2 H200 AC plate pulse generator in the double diode configuration (V = 575). At 1 Torr, the pulsation rate
went from 20 PPS in air to 1300-1400 PPS in argon. With 29 12V cells in the charge pack, input currents ceased
to flow into it. Under these conditions, the tube potential across the plates decreased and the drop across the
input resistor increased. The value of E (= V/d) became smaller (gap size = 3 cm from plate to axial anode
collector), as the extinction voltage decreased.
2) With frequencies of 400 PPS, the currents flowing into the charge pack fell to zero. Replacing a fast-recovery
type HFR 120 (1200v, 40A) diode bridge by a type MUR 860 (600v, 8A) diode bridge had no effect. When the
amplitude of plate potential oscillations falls below the potential of the charge pack, there is also a tendency to
produce arc discharges. For output currents from the vacuum pulse generator to enter the charge pack, the
number of cells must be reduced so that the potential of the charge pack is low enough to admit the transduced
currents. A reduction from 29 to 23 cells allowed currents of 250 mA to enter the CP, and further reduction to 19
cells doubled these currents (per polarity arm).
3) Our observations show that it suffices under these conditions (CP of 19 cells) to increase the vacuum, so that
the frequency decreases, and the plate potential and the charge pack input currents increase. At 0.1 Torr, the
currents reached 1A DC per plate, and at 0.05 Torr, 2A DC
The interconnection between these factors indicates that the extinction voltage is a function of the PAGD
frequency: the higher the PAGD frequency, the lower the extinction voltage, until empirical (in distinction from
predicted) VAD field values are reached. As a consequence, the start voltage of the charge pack must be
adjusted, by varying the number of cells composing it, so that it lies below the lowest extinction voltage of the
PAGD, for any given geometry and gap distance.
Secondly, as the ion plasma is made more rarefied, the frequency of the emissions decreases, but the peak
values of the output voltage and current per pulse increase. The slower the PAGD and the more rarefied the
atmosphere, the higher is the output energy produced by the system relative to the input energy.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.