REJUVENATIyogababe.onlineWELLNESS · SELF-DISCOVERY · INFORMED CURIOSITY

science · SOURCE BATCH2-006

A Practical Guide to Free-Energy Devices — Patrick J. Kelly

attributed reading edition with marked omissions · 1875 source pages · 1965 native web sections · 742,091 published words

Open first-party PDF viewer

Attributed source edition with marked privacy/code omissions. Original PDF page numbers apply in this viewer.

Contents and coverage · All reading editions · Explanatory guides · Source metadata

Editorial commentary and evidence checks for this source

Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.

A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide

A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.

Full commentary and investigation questions

The source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.

Source page 1636 · section 1716/1965 · approximately 5 minutes

A - 790

A - 790
trapping covering with current concentrating conducting holes over perforated plate electrode is formulated, which
has proved effective producing steady glow plasma discharge within the range of 350 V to 2 KV (2,000 V) and
current up to 850 mA, but most the time around 100 to 300 mA range. This is considered low in compare with
other under-liquid plasma system (i.e. Plasma arc, pulsed high voltage and current electric discharge).
Throughout the experiments, a horizontal reactor was used. However an alternative reactor is a vertical reactor.

INTRODUCTION TO THE EXPERIMENTS
Several groups of experiments have been conducted:
1. Preliminary trial experiments
2. Plasma assisted water electrolysis
3. Reformation of methanol
4. Reformation of emulsified diesel
5. Reformation of LPG as hydrocarbon gas (methane is not available in the market)
6. Decontamination or sterilisation of food drink
7. Reduction experiment of TiO2.

In the preliminary trial experiments a number of electrode types have been adopted and have eventually select
the wire to plate configuration and perforated plate to perforated plate or wire mesh as the most suitable under the
limiting power supply condition where max. voltage available is 2,000 V and the maximum current is 1,200 mA.
In reality, the current input is voluntarily restricted to work below 900 mA for durations not exceeding 30 minutes,
to avoid damage to the converter which has happen in a number of occasion which caused stoppage of the
experiments for weeks.

To overcome the power supply limitation, and to achieve steady plasma glow discharge, a gas-retaining or
trapping cover or layer with current concentration holes has been devised to cover the discharging electrode
surface (perforated electrode plate) which is the basic features adopted in the construction of reactor.

In the trial experiments, it has been demonstrated that infrequent visual plasma discharge begins with a voltage of
350 V and steady plasma can be achieved in around 550 V. The initial current input reaches 850 mA and begins
to fluctuating in the range of 150 to 650 mA. On many occasions the current fluctuated at 100 mA to 350 mA.

Through these experiments, the mechanism of generating bubbles or gas pocket dielectric barrier which impedes
the current flow, leading to an increase of voltage until a threshold voltage is reached which causes the electric
breakdown and the formation of plasma inside the bubble, at which point the current immediately returns to its
normal level and then another cycle of discharge is established. When the discharge is infrequent it resembles a
corona streamer discharge but as the voltage increases, the glow discharge becomes a continuous glow over an
extend electrode surface resembling a glow plasma discharge. The colour of the discharge appears as an
orange-yellow or red colour in the electrolysis of water and the temperature of the discharging electrode ranges
from 50OC to about 90OC and the temperature of the bath liquid ranges from 40OC to 70OC. No sign of any
damage to the electrode or its covering plastic gas trapping plate was observed even after prolong
experimentation. When the voltage is allowed to increase beyond the glow plasma region, a plasma arc begin to
occurs and becomes an intensive bright blue discharge when voltage is further increased and this causes
damage to the metal electrode and plastic covering plate which is easily seen.

On two occasions, hydrogen production was recorded which produced a gas volume with an equivalent energy
conversion efficiency up to 56%. Due to damage to the reactor by the plasma arc, that particular experiment
cannot be repeated as new model of reactor is designed to achieve low current input and early high voltage
response. However with the apparent success of the trial experiment, it shows that a more suitable reactor can
be designed specifically for the purpose of hydrogen production by plasma assisted water electrolysis and a
higher energy efficiency figure can be achieved with a small reactor.

PLASMA ASSISTED WATER ELECTROLYSIS
Experiments to check the behaviour of plasma discharge at different voltage input levels were carried out. Despite
the apparently large volume of bubbles boiling inside the reactor, the total volume of gas produced was
unexpectedly low. This may have been caused by the horizontal reactor design adopted throughout the
experiments. This may have allowed the hydrogen gas recombine with the hydroxyl ions and convert back into
water again. A vertical reactor would be more suited for the plasma assisted water electrolysis where the
produced hydrogen gas will rise quickly to the top of the reactor and can be channeled away from the area filled
with OH ions.

In this experiments plasma discharge begin to occur at 1,350 V with current fluctuating around 100 mA to 200 mA.
At about 1,550 V the reactor produced highest volume of gas. Plasma arc discharge occurs at 1,900 V and is

This full section as JSON

Congratulations. You’ve won a support ticket.

Your prize is an email address. No purchase required—but coffee helps keep this place online.

Open a support ticket: azmin@zedec.ai

Support and privacy requests are free. Response times are not guaranteed.

The ceremonial small print

“Due to unusual call volume and support volume, we are experiencing longer than normal wait times for a response.” This is our satirical holding message, not a measured queue report. We offer email support.

America runs on coffee, Britain puts the kettle on, and the opium trade reminds us that empires have had considerably worse business plans.

Donation is optional. No prize draw, purchase verification or guaranteed response is involved. Mandatory legal response duties still apply.

Public-interest research, not a spy drop. We keep 18 U.S.C. § 793 on the reading list—and restricted material off the guest list.

Site support and inquiries are welcome: azmin@zedec.ai. We reserve the right to remain silent, subject to legally required responses.