A - 791
A - 791
becoming vigorous when the voltage is increased further. KOH of 0.02% concentration has been used as
electrolyte additive throughout the experiment.
The production of gas appears to have a linear relation with time but various substantially with different voltage
input. The rate of energy consumption is increasing slowly with time in a constant rate which various with the
voltage input and its corresponding energy consumption per unit gas volume produced is having a peak at the first
10 minutes of the experiments and level off with time. The temperature in the electrode rise sharply to from 50OC
to 90OC and is maintained more or less at that level throughout the test. The temperature in the bath liquid within
the reactor rises slowly from its ambient temperature to around 50OC to 55OC.
EXPERIMENTS WITH METHANOL
Several sets of tests have been conducted with the aim of finding out how different hydrocarbon fuels will be
affected by the non-thermal plasma under-liquid system. A methanol / water mixture with methanol
concentrations of 5%, 10%, 15%, 20%, 25%, 30% and 40% were tested using the same method and equipment
set-up already used for the plasma-assisted water electrolysis. There are three independent tests for each
methanol concentration. It has been observed that the gas production is peaked at 25% methanol concentration
and the energy consumption per unit gas volume produced is also lower than the others and is nearly at constant
rate around 0.0225 Kw.h/L. The voltage input for each test is kept at 1,850 V and the current fluctuating in the
range of 100 mA to 200 mA. The temperature measured at the cathode electrode started at 80OC and rose
quickly to reach over 200OC at the end of a 30 minute experiment. The temperature recorded in other tests
stayed within the range of 60OC to 80OC. The temperature of bath liquid at 25% concentration stayed in the range
of 50OC to 60OC, which is typical for each of these tests.
The greatest surprise coming out of the experiments is that the produced gas is composed of two gases. One is
hydrogen gas and the other is oxygen gas and no trace of carbon dioxide is found. Repeated examination of the
gases produced shows the same result and the hydrogen is having an average value of 51.3% and oxygen
48.7%. This is later found out that the presence of oxygen in the gas is the result of the removal of the separating
diaphragm. An acidic electrolyte is preferable in order to increase the hydrogen gas percentage in the output gas
mix. This is shown in the latest experiments using sulphuric acid of 0.02% concentration.
A set of experiments with the use of 40 KHz ultrasonic bath having methanol concentration of 10%, 15%, 20%
and 25% with the same reactor and equipment arrangement have been conducted to find out the influence of
ultrasonic radiation. It has been observed that gas production at 25% is substantially higher than the others and
yet the energy consumption per unit gas volume produced is around 0.015 Kw.h/L throughout the 30 minute
experiment, which is lower than that without ultrasonic radiation.
The chromatographic analysis of the output gas having an average value of 97.56% hydrogen and 2.4039% of
carbon monoxide. Chromatographic analysis of gas produced by reformation of methanol with ultrasonic
radiation. Methanol concentration at 25%, and conductive reagent 0.02% sulphuric acid.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.