Source page 1638 · section 1718/1965 · approximately 3 minutes
A - 792
A - 792
TABLE 1
Test
Resident time
minutes
Composition
V/V %
Gas type
First Test
0.364
98.9937
H2
1.047
1.0063
CO
Second Test
0.364
96.7418
H2
1.047
3.2582
CO
Third Test
0.354
96.9719
H2
1.048
3.0281
CO
Average
97.5691
H2
2.4309
CO
EXPERIMENTS WITH LPG
Decomposition of LPG by under-liquid plasma has been conducted (methane or natural gas is preferred but none
is available in the market). The LPG is allowed to pass through the horizontal reactor through the perforated
anode plate and enter the reactor and trapped at the cathode plate where plasma is taking place at voltage 1980V
and current at 100 to 130 mA input. C3H8 and C4H10 are the two main components of LPG, it is expected that the
volume output having been subjected to plasma dissociation should be larger than the original input volume. This
is found to be so that the output gas volume increases by about 50%. The experiment is conducted together with
ultrasonic radiation. It is regrettable that the chromatogram is incapable of undertaking analysis of the output gas
composition. The next set of experiments should be conducted with methane or natural gas so that more
definitive result could be obtained. Rudimentary analysis of the produced gas has shown the presence of H2,
CO2 and C3H6 etc.
REFORMATION OF EMULSIFIED DIESEL AND WATER WITH ULTRASONIC IRRADIATION
Decomposition of emulsified diesel with distilled water has also been carried out. Diesel oil in 25% and 50% by
volume has been emulsified by adding 1.25% emulsified agent inside the ultrasonic bath. Since the diesel oil is
dielectric, a KOH additive is needed. The emulsified liquid is subjected to plasma discharge at a voltage of 1,850
V and a current fluctuating from 100 mA to 200 mA for a period of 30 minutes. The temperature of the cathode
electrode increased from 70OC to about 94OC during the experiment. The gas volume produced was 160 ml with
25% diesel and 1,740 ml with 50% diesel, which is substantially higher and its energy consumption is 0.1213
KWh/L. It is clearly indicated, that gas production is proportional to the diesel contend in the emulsion. Because
of the limited power supply capability, the voltage of 1,850 V is merely adequate to produce some plasma
discharge but it is far from establishing extensive vigorous plasma with higher current and voltage input, which
would produce more gas.
STERILISATION (DECONTAMINATION) OF MULBERRY FRUIT DRINK
The ability of non-thermal plasma to decontaminate noxious chemicals and gases has already established. This
experiment is conducted to find out how well the under-liquid plasma may apply in the field of beverage
sterilisation with low levels of plasma radiation and keeping the treated liquid within an acceptable temperature.
Two litters of 15% concentrated fruit drink is placed in the bath where a horizontal reactor is submerged. The
bacteria count and mold colony count is obtained before the forty minute test. A sample of the fruit drink is
extracted at 20 minutes and 40 minutes. The mulberry drink has good natural conductivity so no additive is
required. The applied voltage is kept at 1,200 V and the current fluctuates around 200 mA. The temperature at
the electrode is maintained at around 62OC and the bath liquid (fruit drink) is kept at around 50OC.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.