10 - 100
10 - 100
2. Abnormally high current is caused by high leakages between cells. This will require re-building or re-sealing of
the electrolyser case.
3. If current starts higher then drops off, this means that the plates are contaminated. Take the plates out of the
electrolyser and start over again from plate preparation.
4. Any time there is uneven voltage distribution between cells in a series cell, it means that there is either a large
variation in surface preparation from cell to cell, or there is ion leakage between the cells. Surface preparation
issues will tend to show up as one or more cells having higher voltage, but not in any specific order. Ion
leakage (also called bypass leakage) shows up as uneven voltage distribution, typically higher at the end cells.
Voltage distribution should be even, and within a few hundredths of a volt. Variation of tenths of a volt means
that there is a major problem. Make sure there are no holes drilled in your plates, and make sure that your
plates are very tight in the slots. Check for any place at all for liquid to flow, as this will allow ion leakage to
bypass your central "floating" plates. You may need to use marine GOOP to fix the issue.
Building the Electronics:
Resonant operation of the electrolyser requires the use of a DC pulsing system. Bob has designed an advanced
system for this, consisting of a sophisticated electronics board and a finely-tuned toroidal transformer which
interfaces and matches the electronics to the electrolyser.
The electronics board produces three separate frequencies which are combined together to give a rich and
complex output waveform further modified by the toroidal transformer:
In Bob’s electrolyser build, those frequencies were about 42.8 KHz, 21.4 KHz and 10.7 KHz but please don’t get
the wrong impression here, there is no single exact frequency or set of frequencies which should be used. The
size and shape of your cell, the electrodes spacings, electrolyte density, electrolyte temperature and operational
pressure are all factors which affect the tuning of the electronics. With Bob’s large marine-duty cells with square
twelve-inch plates, he found the base resonance point using his original, modified inverter, to be at least 100 Hz
lower than that of the prototypes with smaller plate sizes. That inverter is no longer commercially available and
even if it were, it would not be used as Bob’s electronics board is far more effective. The triple-oscillator board
can be tuned with an oscilloscope but if one is not available, then the preset resistors are set to their mid-point
and then the 42,800 Hz frequency is adjusted very slowly to find the point of maximum gas output. This is a very
precise point and it is essential to use high-quality preset resistors which vary their resistance very accurately.
The aim is to adjust the frequency by as little as 1 Hz at a time. When the optimum point is found, then the
procedure is repeated with the 21,400 Hz frequency generator, and finally the 10,700 Hz frequency adjustment.
Last of all, the Mark/Space ratio presets are adjusted to give the lowest pulse width which does not reduce the
rate of gas generation.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.