Source page 499 · section 514/1965 · approximately 5 minutes
10 - 99
10 - 99
over” it will contain the spillage. Add only a small amount of KOH at a time, stirring continuously, and if you stop
stirring for any reason, put the lids back on all containers.
If, in spite of all precautions, you get some KOH solution on your skin, wash it off with plenty of running cold water
and apply some vinegar to the skin. Vinegar is acidic, and will help balance out the alkalinity of the KOH. You can
use lemon juice if you don't have vinegar to hand - but it is always recommended to keep a bottle of vinegar
handy.
Plate Cleansing:
Plate cleansing is always done with NaOH. Prepare a 5% to 10% (by weight) NaOH solution and let it cool down.
A 5% solution ‘by weight’ is 50 grams of NaOH in 950 cc of water. A 10% solution ‘by weight’ is 100 grams of
NaOH in 900 cc of water. As mentioned before, never handle the plates with your bare hands, but always use
clean rubber gloves. Put the sanded and rinsed plates into the slots in the electrolyser case, keeping them all the
same way round so that they remain magnetically matched. Fill the electrolyser with the NaOH solution until the
plates are just covered.
A voltage is now applied across the whole set of plates by attaching the leads to the outermost two plates. This
voltage should be at least 2 volts per cell, but it should not exceed 2.5 volts per cell. Maintain this voltage across
the set of plates for several hours at a time. The current is likely to be 4 amps or more. As this process
continues, the boiling action will loosen particles from the pores and surfaces of the metal. This process produces
hydroxy gas, so it is very important that the gas is not allowed to collect anywhere indoors (such as on ceilings).
After several hours, disconnect the electrical supply and pour the electrolyte solution into a container. Rinse out
the cells thoroughly with distilled water. Filter the dilute NaOH solution through paper towels or coffee filters to
remove the particles. Pour the dilute solution back into the electrolyser and repeat this cleaning process. You
may have to repeat the electrolysis and rinsing process many times before the plates stop putting out particles
into the solution. If you wish, you can use a new NaOH solution each time you cleanse, but you can go through a
lot of solution just in this cleaning stage if you choose to do it that way. When cleansing is finished (typically, after
three days), do a final rinse with clean distilled water. It is very important that during cleansing, during
conditioning and during use, that the polarity of the electrical power is always the same. In other words, don’t
swap the battery connections over as that destroys all the preparation work and requires the cleansing and
conditioning processes to be carried out all over again.
Plate Conditioning:
Using the same concentration of solution as in cleansing, fill the electrolyser with dilute solution up to 1/2" below
the tops of the plates. Do not overfill the cells. Apply about 2 volts per cell and allow the unit to run. Remember
that very good ventilation is essential during this process. The cells may overflow, but this is ok for now. As water
is consumed, the levels will drop. Once the cells stabilise with the liquid level at the plate tops or just below,
monitor the current draw. If the current draw is fairly stable, continue with this conditioning phase continuously
for two to three days, adding just enough distilled water to replace what is consumed. If the solution changes
colour or develops a layer of crud on the surface of the electrolyte, then the cell stack needs more cleansing
stages. Do not allow the cells to overfill and overflow at this point. After two to three days of run time, pour out the
dilute NaOH solution and rinse out the electrolyser thoroughly with distilled water.
Cell Operation:
Mix up a full-strength solution of potassium hydroxide (280 grams of KOH added to 720 cc of water). The filling of
the electrolyser depends on whether straight DC electrolysis is to be used, or resonant electrolysis is to be used.
For straight DC electrolysis, fill the electrolyser to about one inch below the tops of the plates. The DC voltage
applied to the electrolyser will be about 2 volts per cell or a little less, so this 100-cell electrolyser will have 180 to
200 volts applied to it. This voltage will be generated with an inverter.
For resonant operation, fill the electrolyser to only half the plate height because the hydroxy gas production is so
rapid that room has to be left for the gas leaving the plates. With resonant operation, about 1.5 volts per cell is
used.
Troubleshooting:
1. Abnormally low current is caused by improper plate preparation or severe contamination. Take the plates out
of the electrolyser and start over again from plate preparation.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.