Source page 704 · section 723/1965 · approximately 4 minutes
13 - 6
13 - 6
Construction:
If you decide to attempt to build one of these units we suggest using the stated materials:
1. Aluminium Base Plate
2. Sleeve Bearing of oil impregnated brass, 1" long, 0.5" inside diameter.
3. Brass Shaft, 4" long, 0.5" outside diameter
4) Rotor, brass 1.75" long, 2" diameter,
5) Six rotor slots, each 1.75" long, 0.26” deep, 0.72" wide. These slots are spaced exactly 60 degrees apart.
6) One slot cut in centre of Brass Rotor, 360 degrees around, 0.25" wide by 0.313" deep.
7) 12 slots (produced from the six slots when the 360 degree cut is made). Each slot is lined with mica
insulation, 0.01” thick.
8) A total of 228 pieces of U-shaped copper coated steel wires, 0.04” thick. Each slot (7 above) has 19
pieces of these wires fitted into the Mica, thus these wires do not contact the Brass rotor. The leading edge
of these wires is flush with the Rotor’s outer surface and the trailing edge protrudes 1/8" above the Rotor’s
outer diameter.
9) Each of the 12 magnets receives eleven complete turns of 0.032” thick copper coated steel wire. These
11 turns or ‘wraps’ accumulate to 3/8" wide and the same pattern is placed around all 12 magnets. When
placed into the bent wires (8 above), they form a snug fit making firm contact.
10) Twelve pieces of mylar insulation, 0.005" thick, are inserted into the cores of the wires (9 above).
11) The twelve permanent magnets, insulated with the mylar, must not contact wires of 9). These magnets
measure 3/4" long, 5/8" wide, 3/8" thick and are made of a special composition and strength. Alnico 4, M-60;
12 AL, 28 Ni, 5 Cobalt Fe, Isotropic permanent magnet material cooled in magnetic field, Cast 9100 TS. 450
Brin, 2.2 Peak energy product. When inserted in the rotor the outer faces of these 12 magnets are not to be
machined to a radius. The centre of these magnets pass the centre of the coils with 3/32" clearance. The
edges, where the wires are wrapped, pass 1/32" away from the coils. This ‘changing magnet spacing’ aids in
not only the release cycle but also contributes to rotational movement. (Sharp magnet edges which are
facing the coils are to be sanded to a small smooth radius.)
12) Make sure that the magnets are placed in the Rotor with the polarity shown in the diagram.
13) The 12 magnet wire wraps are divided into two sections; 6 upper and 6 lower. There are no connections
between these sections. The magnetic flow direction between the upper 6 wraps and the lower 6 wraps is
attained by the ‘flow direction’. The wires are wrapped around the magnet starting at the top ‘north’ half and
then after 11 complete turns the wire exits at the lower ‘south’ half. As this wire then goes to the next
magnet it arrives at an attract wire which is its ‘north’ side. Thus all wires get interconnected from south to
north magnet half or north to south magnet half. The actual connections should be crimped copper clips (not
solder) with insulation tubing to prevent contact to the Rotor body.
14) A 0.03” thick copper tube (stiff material) 2" long by 2½" inside diameter.
15) Six slots are cut at the top of tube #14. These slots are 5/8" wide by 1/32" deep spaced at 60 degrees
apart.
16) Six slots are cut at the bottom of tube #14. These slots are 5/8" wide by 5/16" deep and in line with the
upper slots #15.
17) There are six copper tube mounting points.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.