Source page 705 · section 724/1965 · approximately 5 minutes
13 - 7
13 - 7
18) An acrylic ring is used to hold Part #14, measuring 3.75" outer diameter and 2.25" inner diameter, 3/8"
thick, bolted directly to Part #1. This ring has a 0.03” wide groove cut 0.25” deep to allow the six copper tube
mounting points to be inserted (part 17).
19) Plastic insulation paper, 0.002" thick, is to be placed around the inside and outside of Part #14.
20) There are six coils of insulated copper wire, each coil having 72 turns of .014 thick wire. Each coil is
wound with two layers, the bottom layer completely fills the 5/8" wide slot with 45 turns and the top layer
spans 5/16" wide with 27 turns. To be sure each coil has the exact wire length of 72 turns, a sample length
wire is wrapped then unwound to serve as a template for six lengths. A suggested coil winding method is to
fill a small spool with one length then by holding the copper tube at the lower extension, then start at the plus
wire in Figure 2 and temporarily secure this wire to the outer surface of the tube. Next, place the pre-
measured spool of wire inside the tube, wrapping down and around the outside advancing clockwise until
the 5/8" slot is filled with 45 turns. Then, return this wire back across the top of the coil for 15/32" and
winding in the same direction again advance clockwise placing the second layer spanned for 5/16" with 27
turns. This method should have the second layer perfectly centered above the first layer. After winding this
coil, repeat the process, filling the small spool with another length of pre-measured wire. A very important
magnetic response happens as all six coils have their second layers spaced in this way..
22) Item 22 above shows the connection pattern for six coils. When the unit is driven at start-up (hand crank)
for 42 seconds at 2100 RPM, all six jumper wires must be together which means the plus wire goes to the
minus wire connected by the start switch. After 42 seconds the load is added to the circuit and the start
switch is opened. To double check your connections between the coils, note that the finish wire of coil #1
goes to the finish wire of coil #2, which is top layer to top layer. This pattern then has start of coil 2 (bottom
layer) going to start of coil 3 (also bottom layer). When the copper tube with the coils is placed around the
rotor, the distance from any magnet to any coil must be identical. If it measures different, acrylic holding
shapes can be bolted to the aluminium base, protruding upward, and thus push the copper tube in the
direction needed to maintain the spacing as stated.
23) Wires to load.
24) Wires to start switch.
25) Rotational direction which is clock—wise when viewing from top down.
26) Acrylic dome for protection against elements.
27) Coating of clear acrylic to solidify rotor. Do not use standard motor varnish. Pre-heat the rotor and
then dip it into heated liquid acrylic. After removal from dip tank, hand rotate until the acrylic hardens, then
balance rotor. For balancing procedure, either add brass weights or remove brass as needed by drilling
small holes into rotor on its heavy side.
28) Insulation tubing on all connections.
29) Shaft for start purposes and speed testing (if desired).
The reason that this generator is included in this chapter is because the construction is quite complex. Also,
the plans have been around for several years without my being aware of anyone constructing or operating
one of these units.
Cold Fusion. Cold fusion was initially accepted with great excitement. It then appeared to be discredited.
However, at the present time, there are been some two hundred labs. which have confirmed the findings and
so there is no doubt as to the reality of the system. In essence, it is said that nuclear fusion can take place
at room temperature, under certain conditions. However, developers are struggling to develop a serious
working device and although the process has now been confirmed without a doubt, a practical free-energy
device based on this method appears to be some time away yet.
There are several web sites which follow the progress in this field, including “Cold Fusion Times” at
http://world.std.com/~mica/cft.html where considerable detail is available.
Moller’s Atomic Hydrogen Generator. One already successful experiment can be found at
http://jlnlabs.imars.com/mahg/tests/index.htm where the highly resourceful researcher JL Naudin shows
many successful tests on a system which can be found at the http://jlnlabs.imars.com/mahg/article.htm
website. Please check out these very well presented sites. This system should not be called the “Moller”
system as it was originated by William Lyne and published in his book “Occult Ether Systems” in 1997.
William Lyne states that in 1999, Nikolas Moller bought a copy of his book and subsequently claimed that he
(Moller) had invented the Atomic Hydrogen Generator, quoting directly from Lyne’s book. This system
should be called the “Lyne Atomic Hydrogen Generator”.
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.