Important Note
Gary of G. L. Chemelec commenting on “The HydroStar” circuit which sounds to be based on the same style
of circuitry, states that the circuit and design are riddled with serious errors, some of which are:
1. The use of the 741 WILL NOT WORK! Pin 5 is a Voltage Control pin that already has its own voltage of
2/3 of the Supply voltage so it requires a pull down resistor, not an IC to control it.
2. The 2K Pulse width adjust will blow the 555 timer if adjusted all the way down. It needs an additional
resistor to limit current to those pins on the IC.
3. The output of the 555, Pin 3 is fed to the CD4059 as well as a TC4420CPA (Mosfet Driver). This driver is
a waste of money as it is not needed.
4. The Output of the TC4420CPA is then fed to the IRF510 Mosfet which is now obsolete, however you can
use an RFP50N06 (50V, 60A).
5. There is no schematic of the CD4059. They should have shown pin 1 as in, pin 23 as out, pins 3, 10, 13,
14, and 24 connected to 12 volts and pins 2, 4, 5, 6, 7, 8, 9, 11, 12, 15, 16, 17, 18, 19, 20, 21, and 22
connected to ground.
6. The "Strength Adjust" Only Needs the variable resistor connected to Pin 5 and the Ground. The
Connection of this control to the Supply Voltage Make Absolutely No Difference in the Output
Waveforms, as the IC only needs a 2/3's voltage on this Pin and this is supplied internally, Within the IC.
7. The "Frequency Adjust", Connects to Pins 6 & 7 of This 555. Supply to the battery Will Destroy the 555.
so another resistor is needed to prevent this from happening.
This is just a small list of what is wrong. There is MUCH MORE and even after the thing is built it does NOT
WORK! If you want to experiment then please do, but I would suggest you just make your own Pulse Width
Modulator.
There are also many problems with the design of the reaction chamber and simply put, even if you did get it
to work you would need more of these units than you could ever fit in your car to even think about running
the engine. Simply put, the unit will NOT create enough gas to run much of anything. Don't get me wrong, I
do think that the idea is GREAT and that it can be done.
Reaction chamber:
The suggested reaction chamber arrangement is:
It is suggested that you use a section of 4" PVC waste pipe with a threaded screw-cap fitting on one end and
a standard end-cap at the other. Make sure to drill-and-epoxy or tap threads through the PVC components
for all fittings. Set and control the water level in the chamber so that the pipe electrodes are well covered and
there is still ample headroom left to build up the hydrogen/oxygen gas pressure. Use stainless steel wires
inside the chamber or otherwise use a protective coating; use insulated wires outside. Ensure that the epoxy
seals are perfect or alternatively, lay down a bead of water-proof silicone sufficient to hold the pressure.
The screw fitting may require soft silicone sealant, or a gasket. Its purpose is to maintain the pressure in the
cylinder and yet allow periodic inspection of the electrodes. Make sure that there are no leaks and you will
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.