Source page 914 · section 938/1965 · approximately 3 minutes
A - 68
A - 68
Fig.6 shows a similar flux pattern for flux between carousel magnets 25A and 25B and inboard rotor magnet 19.
Again the lines emanating from carousel magnet 25A and passing through rotor magnet 19 produce flux linkages
in coil 17 that are opposite in sense from those produced by lines from magnet 25B.
The arrangement of the carousel magnets with the north poles facing each other tends to confine and channel the
flux into the desired path. This arrangement replaces the function of magnetic yokes or laminations of more
conventional generators.
The flux linkages produced by magnets 25A and 25B are opposite in sense regardless of the rotational position of
coil 17 including the case where coil 17 is aligned with the carousel and rotor magnets as well as for the same
coils when they are aligned with an unpopulated rotor sector.
Taking into account the flux patterns of Fig.4 and Fig.6 and recognising the opposing sense conditions just
described, net flux linkages for a given coil 17 are deduced as shown in Fig.7.
In Fig.7, net flux linkages (coil-turns x lines) are plotted as a function of coil position in degrees. Coil position is
here defined as the position of the centreline 35 of coil 17 relative to the angular scale shown in degrees in Fig.6.
(Note that the coil is stationary and the scale is fixed to the rotor. As the rotor turns in a clockwise direction, the
relative position of coil 17 progresses from zero to ten to twenty degrees etc.).
At a relative coil position of ten degrees, the coil is centred between magnets 25A and 25B. Assuming
symmetrical flux patterns for the two magnets, the flux linkages from one magnet exactly cancel the flux linkages
from the other so that net flux linkages are zero. As the relative coil position moves to the right, linkages from
magnet 25A decrease and those from magnet 25B increase so that net flux linkages build up from zero and
passes through a maximum negative value at some point between ten and twenty degrees. After reaching the
negative maximum, flux linkages decrease, passing through zero at 30 degrees (where coil 17 is at the centre of
an unpopulated rotor sector) and then rising to a positive maximum at some point just beyond 60 degrees. This
cyclic variation repeats as the coil is subjected successively to fields from populated and unpopulated rotor
sectors.
As the rotor is driven rotationally, net flux linkages for all eighteen coils are altered at a rate that is determined by
the flux pattern just described in combination with the rotational velocity of the rotor. Instantaneous voltage
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.