Source page 915 · section 939/1965 · approximately 3 minutes
A - 69
A - 69
induced in coil 17 is a function of the slope of the curve shown in Fig.7 and rotor velocity, and voltage polarity
changes as the slope of the curve alternates between positive and negative.
It is important to note here that a coil positioned at ten degrees is exposed to a negative slope while the adjacent
coil is exposed to a positive slope. The polarities of the voltages induced in the two adjacent coils are therefore
opposite. For series or parallel connections of odd and even-numbered coils, this polarity discrepancy can be
corrected by installing the odd and even numbered coils oppositely (odds rotated end for end relative to evens) or
by reversing start and finish connections of odd relative to even numbered coils. Either of these measures will
render all coil voltages additive as needed for series or parallel connections. Unless the field patterns for
populated and unpopulated sectors are very nearly symmetrical, however, the voltages induced in odd and even
numbered coils will have different waveforms. This difference will not be corrected by the coil reversals or reverse
connections discussed in the previous paragraph. Unless the voltage waveforms are very nearly the same,
circulating currents will flow between even and odd-numbered coils. These circulating currents will reduce
generator efficiency.
To prevent such circulating currents and the attendant loss in operating efficiency for non symmetrical field
patterns and unmatched voltage waveforms, the series-parallel connections of Fig.8 may be employed in a high-
current, low-voltage configuration of the generator. If the eighteen coils are numbered in sequence from one to
eighteen according to position about the stator, all even-numbered coils are connected in parallel, all odd-
numbered coils are connected in parallel, and the two parallel coil groups are connected in series as shown with
reversed polarity for one group so that voltages will be in phase relative to output cable 16.
For a low-current, high voltage configuration, the series connection of all coils may be employed as shown in
Fig.9. In this case, it is only necessary to correct the polarity difference between even and odd numbered coils.
As mentioned earlier, this can be accomplished by means of opposite start and finish connections for odd and
even coils or by installing alternate coils reversed, end for end.
For intermediate current and voltage configurations, various series-parallel connections may be employed. Fig.10,
for example, shows three groups of six coils each connected in series. Circulating currents will be avoided so
long as even-numbered coils are not connected in parallel with odd-numbered coils. Parallel connection of
Editorial commentary and evidence checks for this source
Check definitions, measurements and the difference between a model, a reported simulation and independently reproduced evidence. Spiritual or speculative interpretations do not become physical or clinical findings through notation.
A Practical Guide to Free-Energy Devices — Patrick J. Kelly — evidence guide
A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
An archive is a starting point, not an automatic truth certificate. A large technical compilation mixes ordinary electrical mechanisms with unvalidated excess-energy claims. Require complete energy accounting, independent replication and safe experimental design.
Full commentary and investigation questionsThe source text is preserved as attributed material; commentary does not rewrite an allegation into a verified finding.